955205_01 11/11 7
Installing RowFlow Liquid System (Planter)
Liquid system
Installaon of liquid tank, pump, lines, etc. is le to the discreon of the grower.
RowFlow system
Refer to RowFlow Installaon Guide to install components of the RowFlow system.
Hydraulic Motor
If installing a new Precision Planng Hydraulic Motor (727105), please refer to installaon guide
included with motor for installaon instrucons. The motor may be aached to the liquid pump
with a direct coupler or a chain & sprocket combinaon.
Pressure Sensor and Flow Meter
The Pressure Sensor (727301) should be installed into a diagnosc “T” (not provided by
Precision Planng) somewhere between the liquid pump and the applicaon. Placement of the
sensor is not crical. The grower should understand that dierent pressures can be measured
at dierent points (main line versus individual row line) and where the sensor is installed is the
only point at which pressure can be measured. NOTE: Threaded ng for the Pressure Sensor is
¼” NPT.
The Flow Meter (727305/727306) should be installed between the liquid pump and the
distribuon to the rows. All ow should pass through this meter. The Flow Meter should be
installed vercally with approximately six inches before and aer that are free of any
impediments and sharp objects. There is no specic direcon of travel to factor into installaon.
The green ow sensor threads all the way into the housing and then locked with the jamnut.
NOTE: Thread tape or sealant should be used on all threaded connecons, ow meters, and
pressure sensors where.
Connecng Components
Idenfy two Row Unit Modules (RUM) that have open AUX connecons (6-pin Deutsch). Other
components that may be plugged into the AUX connecon could be a Vacuum Sensor, Posive
Air Sensor, or a Li Switch. These will be used to connect the Pressure Sensor and Flow Meter
into the system. Connecng the Pressure sensor to a RUM AUX plug will require the use of the
15’ Pressure Sensor Harness (727302). If addional length is needed, a 12’ 6-pin Deutsch
extension (727304) may be necessary. Connecng the Flow Meter Sensor to a RUM AUX plug
will require the use of the 15’ Flow Meter Harness (727303). If addional length is needed, a 12’
6-pin Deutsch extension (727304) may be necessary.
The hydraulic motor harness (727111 - for the motor driving the liquid pump) may be
connected to any of the three Drive Motor (8-pin Deutsch) connecons on the RowFlow Base
Harness.