Premium PAC9039 - Power, Motor, and Heating Fault Diagnosis

Premium PAC9039
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
6
One of indoor unit works normally.
but one of indoor unit has no
response to signals of remote
controller.
One of indoor unit works as cooling or
dehumidific
ation mode. Another one indoor
unit can’t work as heating mode. The mean is
that the indoor unit with heating mode
couldn’t receive single from remote controller.
2. No power supplyout of
work completely-tentative diagnosis
2.1. Check item
1) Does the input voltage is correct
2) Does AC power wires connected correctly
3) Does the output voltage of voltage stabilizer l7805 (ic2) is correct
4) Does between indoor and outdoor unit communication is normal
2.2. Fault diagnosis procedure
NoteThere is according with an outdoor unit and two indoor unit. and a set of PCB. Please
check them accordingly.
1 Unplug the indoors and outdoors and re-plug after about 5 seconds
2 Listen if noise from buzzer or not?