E22
T3 EMPTY
When the water recovery kit is activated and the machine detects that there is no
“Min level Tank 3” while filling from T3.
Buzzer is activated for 20 seconds. The machine stops filling from T3 and
switches to filling normally with cold water. The warning disappears when the next
cycle starts.
E23
ERROR IN WEIGHT
This message appears when the machine detects that there is no signal from the
weight sensor, the weight is less than 0 or more than 20% of the nominal load of
the model configured, provided the weight control kit is active.
The programme will be allowed to run normally without a weight control.
E24
TRANSFER ERROR
If the transfer between the PC and USB is not completed correctly, this warning is
displayed.
OK to accept.
E25
COMMUNICATION
ERROR CONTROL-
CONTROL AUX.
This warning is triggered when no communication is detected between the main
control card and the auxiliary control card.
If the washing machine is not running, the error is displayed but the programmes
which do not involve the auxiliary control card can be run.
If the error is triggered while the machine is running, the warning is displayed
together with the message “end”, ending the programme and unlocking the door
when the button is pressed.
E26
MOTOR HOT WIRE /
VARIATOR ERROR
This error occurs when at any time of the execution of a program, the entry
"Thermal Motor" is opened.
Only the option "end" is given, the programme ends, and the door is unlocked
when this button is pressed.
E27
ERROR NTC OUT OF
RANGE
This error occurs when a temperature value is measured that is above the
configured range (currently the maximum valid value is 110 ºC). This means that
the NTC is broken or disconnected. On detecting that the NTC is out of range, "- -"
is displayed instead of the temperature value.
The 2 options "OK" or "Cancel" are displayed. Press "OK" to continue with the
programme as if the temperature had been reached and consequently skip the
heating phase. Press “Cancel” to end the programme, and unlock the door.
E28
ERROR PRESSURE
SENSOR OUT OF RANGE
This error occurs when a voltage value is measured of less than 0.4 V or more
than 3.8 V. This means that the pressure sensor is broken or disconnected.
Only the option “OK” exists. Press “OK” to end the programme, and unlock the
door.