A programme execution finishes but the water temperature inside the tub exceeds
50 ºC.
The 2 options "continue" or "end" are displayed. If we press continue, the machine
again checks the temperature, unlocking the door only if it has dropped below
50ºC. The same message is displayed again if the temperature has not
decreased. If we press “end”, the programme will end and the door unlocks.
The machine detects that the door cannot be unlocked at the end of a programme.
This error occurs after 3 attempts to unlock the door every 20 seconds.
Only the option "end" is given. When this option is pressed, the machine repeats
the 3 attempts to unlock and if it cannot unlock the door the error is given with the
following text: “DO NOT FORCE THE DOOR. CALL THE TECHNICAL SERVICE”.
On trying to select the model, the machine does not detect an activated range
input (low, medium, high, sanitary) or more than one range is activated.
The option "back" is given to exit the menu, returning to the screen where the
model code is entered.
When the weighing kit is active, the inputs “front pressure switch” and “Rear
pressure switch” are found to be deactivated.
The option “end” is displayed if the machine is currently running a programme.
While the weighing kit is active, when the output “front inflation” is activated and
the input “Front pressure switch” is not opened for 5 minutes.
While the weighing kit is active, when the output “rear inflation” is activated and
the input “Rear pressure switch” is not opened for 5 minutes.
When the water recovery kit is activated and the machine detects that the input
“Max level Tank 1” has activated while draining to T1.
Buzzer is activated for 20 seconds. The machine stops draining to T1 and
switches to normal drainage. The warning disappears when the next cycle starts.
When the water recovery kit is activated and the machine detects that there is no
“Min level Tank 1” while filling from T1.
Buzzer is activated for 20 seconds. The machine stops filling from T1 and
switches to filling normally with cold water. The warning disappears when the next
cycle starts.
When the water recovery kit is activated and the machine detects that the input
“Max level Tank 2” has activated while draining to T2.
Buzzer is activated for 20 seconds. The machine stops draining to T2 and
switches to normal drainage. The warning disappears when the next cycle starts.
When the water recovery kit is activated and the machine detects that there is no
“Min level Tank 2” while filling from T2.
Buzzer is activated for 20 seconds. The machine stops filling from T2 and
switches to filling normally with cold water. The warning disappears when the next
cycle starts.
When the water recovery kit is activated and the machine detects that the input
“Max level Tank 3” has activated while draining to T3.
Buzzer is activated for 20 seconds. The machine stops draining to T3 and
switches to normal drainage. The warning disappears when the next cycle starts.