Instructions for use
IMPORTANT: Read these instructions carefully
before connecting the appliance to the LP
Gas cartridge or fuel bottle, and then study
the instructions for use regularly in order
to remember the way the appliance works.
Keep these instructions for future use. Failure
to follow these instructions can result in
serious personal injury and death!
WARNING: This appliance consumes oxygen
and produces carbon dioxide. To avoid
extreme danger, do NOT ignite this appliance
in unventilated space, indoors, in a tent, in a
vehicle or other enclosed space.
USE OUTDOORS ONLY!
NEVER cover the stove, LP Gas cartridge or
fuel bottle with windscreen, stones or similar,
that can cause overheating and damage to the
stove, LP Gas cartridge or to the fuel bottle.
Overheating the LP Gas cartridge or the fuel
bottle in this way is extremely dangerous. Use
the windscreen that accompanies the stove.
Fuel and performance
Jet 32 - LP Gas
• Primus cartridge LP Gas (propane/butane
mix) is the ideal fuel for the EtaPower MF
stove. The fuel is very easy to use, normally
requires no priming, and is efcient,
environmentally friendly and clean (no soot).
Minimum maintenance and cleaning are
required.
Jet 28 - Petrol/Gasoline
• Good quality industrial petroVgasoline, such
as PRIMUS PowerFuel, MSR® White Gas and
Coleman® Fuel give clean burning and leave
almost no deposits in the fuel system.
• Unleaded petroVgasoline is extremely
volatile and contains additives that leave more
deposits in the fuel system.
• Do NOT use leaded petrol/gasoline, because
of the health risks involved.
Jet 22 - Parafn/Kerosene
• Parafn/kerosene can be obtained
throughout the world, but burns with a smoky
ame, it is also more difcult to preheat and
requires regular cleaning.
1. Introduction
1.1 This appliance is intended for PRIMUS
PowerGas (Propane/isobutane/Butane mix)
2202, 2206 and 2207 or PRIMUS PowerFuel
or other high-grade industrial petrol/gasoline,
unleaded petroVgasoline and parafn/
kerosene.
1.2 Use Primus LP Gas cartridges/fuel
bottles, Any attempt to t another type of LP
Gas cartridges or liquid fuel bottle may be
dangerous. This may result in leakage, leading
to injury or death.
1.3 Gas consumption 116 g/h / 5700 BTU/h /
approx. 1.61 kW at 1 bar gas pressure.
1.4 Size of jet: 0.32 mm, (733950) for LP Gas.
Jet size: 0.28 mm, (734330) for industrial
petrol/ gasoline such as PRIMUS PowerFuel,
MSR® White Gas, Coleman® Fuel and
unleaded petrol/gasoline. Jet size: 0.22 mm,
(734320) for parafn/kerosene or similar fuel.
1.5 The appliance fulls requirements
in accordance with EN 521 and ANSI
Z21.72b-2002/CSA11.2b-2002. The CE
approval (EN 521) regards only LP Gas.
1.6 Ensure at all times that the hose
between the cartridge and stove is straight,
and cannot come In contact with the ame
or hot gases. Avoid subjecting the hose to
wear. Make sure that the HOSE DOES NOT
GET TWISTED.