TIM-94N
Input
Power supply
100 - 250 VAC 50-60 Hz
Communication
Modbus RTU
Ambient operation
Temperature -10 ํC to 60 ํC
Humidity 85 % RH Non-Condensing
Ambient storage
Temperature -20 ํC to 80 ํC
Humidity 85 % RH Non-Condensing
Power consumption
Display
7-Segment, size 0.56 Inch, 5 Digit
Protocol
Material ABS-V0
Size 96 x 80 x 48 mm.
Weight 240 g.
3 VA
Protection degree
IP52Front protection rating
Case protection rating IP30
Baud rate
Parity
Data Bit
Stop Bit
Support device node
1200, 2400, 4800, 9600, 19200, 38400, 57600 bps
None, even, odd
8 bit
1, 2
32
Installation Panel, Mounting
10 - 24 VAC/VDC
3 LED (Show alarm relay)
1 LED (Show communication)
Thermocouple
RTD
± 0.25 % of Measurement range at 25 ํC
Output
3 Alarm 5A 250VAC
Current
Alarm relay
Tranfer current
Tranfer voltage
Output Impedance
4 - 20 mA
0 - 10 VDC
Load 500
Ω for 4 - 20 mA Output
Load 1 k
Ω for 0 - 10 VDC Output
± 0.25 % of Output Range Accuracy
Address 1 - 127
TECHNICAL SPECIFICATION (คุณสมบัติทางดานเทคนิค)
DIMENSION (ขนาดและรูปราง)
Voltage
Accuracy
Sampling time
Type K, J, R, T, N, S, E,
PT100
0-20mA , 4-20mA
0-100 mV, 0-5 VDC, 1-5 VDC, 0-10 VDC
0.25 Sec.
CUTTING PANEL (การเจาะติดตั้ง)
INSTALLATION (การติดตั้ง)
DESCRIPTION (คุณสมบัติ)
)(
อุปกรณวัดและแสดงผลคาสัญญาณอะนาล็อกมาตราฐาน, คาอุณหภูมิ, ความชื้น, Pressure และ Process ตางๆ
มี Alarm relay สําหรับกําหนดเงื่อนไขการใชงานได
- Thermocouple
- Current Analog : 0-20mA, 4-20mA
- Voltage Analog : 0-5 VDC, 1-5 VDC, 0-10 VDC
มี Option Transfer Output 4-20mA / 0-10VDC
GENERAL DESCRIPTION (คุณสมบัติทั่วไป)
UNIVERSAL INPUT DIGITAL INDICATOR WITH ALARMUNIT
- RTD (PT100)
รับสัญญาณอินพุตประเภท
แสดงผลโดย 7-Segment ขนาด 0.56 นิ้ว จํานวน 5 หลัก
สื่อสารผาน Computer โดย RS-485 Modbus RTU Protocol
มี Lock Function ปองกันการเปลี่ยนคา Settiing ผานหนาจอ
LED แสดงการทํางานของ Alarm และ Communication
TIM-94N เปนอุปกรณวัดและแสดงผลแบบดิจิตอล โดยวัดและแสดงผลคาสัญญาณอะนาล็อกมาตรฐาน และ
คาอุณหภูมิและ Process ตางๆ พรอม Alarm Output โดยรับสัญญาณอินพุทประเภท Thermocouple PT100, Current
Analog (0-20 mA, 4-20 mA) และ Voltage Analog (0-5 VDC, 1-5 VDC, 0-10 VDC) มี Alarm Relay Output สูง
สุด 3 Alarm, 4 Alarm function ในการตั้งคาสําหรับตัดตอ Load ไดตามตองการและ Analog Transfer Output สําหรับ
ตอรวมเขากับอุปกรณอื่นๆได สามารถตั้ง Range High-Low Limit สําหรับ Input ตางๆ ไดตาม Table 1.
TIM-94N series เหมาะสําหรับติดตั้งในเครื่องจักรเพื่อ แสดงคาของ Process ตางๆ
DEL ุ
1 mralA
2 mralA
3 mralA
่ื
่ื
่ิ่ื
่ื
WIRING DIAGRAM (วงจรการตอใชงาน)
Jump for
Current Input
Source Transfer Output
10-24 V
100-250V
Max. 5A/250V Max. 5A/250V Max. 5A/250V
Alarm 1 Alarm 2 Alarm 3
24V
30A
Alarm 2
ALARM OUTPUT
TRANSFER OUTPUT
MODBUS PROTOCOL
POWER SUPPLY
ALARM OUTPUT
TRANSFER
OUTPUT
MODBUS
PROTOCOL
POWER
SUPPLY
Alarm 3
B
C
Transfefer 0-10VDC
Transfefer 4-20mA
G
l
RS-485
100-250VAC/50Hz
220
ORDERING CODE (การติดตอสั่งซื้อ)
Question and Answer IconNeed help?

Do you have a question about the Primus TIM-94N and is the answer not in the manual?

Summary

Technical Specifications Overview

Power Supply and Consumption

Details the power source voltage, frequency, and overall consumption.

Display and Input Signal Types

Covers display characteristics and supported input signal types.

Input Signal Accuracy and Timing

Specifies accuracy and sampling time for various input signals.

Output and Communication Features

Details alarm relay, transfer output, and communication protocol.

Environmental and Physical Specifications

Lists operating conditions, protection ratings, material, size, and weight.

Physical Installation and Wiring

Unit Dimensions and Panel Cutout

Shows the physical dimensions of the unit and the required panel cutout.

Wiring Diagram and Ordering Information

Illustrates the electrical connection diagram and provides ordering codes.

Operation Settings and Configuration

Operation Mode and Input Setup

Configures operation mode, input type, and PV correction.

Filter, Decimal Point, and Lock Settings

Adjusts signal filtering, decimal point display, and key lock.

Alarm Function Settings (Alarms 1-3)

Configures functions, high/low limits, and hysteresis for alarms.

Time Delay and Speed Settings

Sets time delays for alarms and communication speed.

Serial Communication and Modbus Protocol

Modbus RTU Communication Setup

Details Modbus RTU protocol, address, parity, and stop bit settings.

Modbus Function Codes and Data Structure

Explains Modbus function codes, register addresses, and data formats.

Primus TIM-94N Specifications

General IconGeneral
BrandPrimus
ModelTIM-94N
CategoryMeasuring Instruments
LanguageEnglish