Princeton Instruments HRS-300 User Manual

Princeton Instruments HRS-300
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Princeton Instruments
15 Discovery Way Acton, MA 01720 USA
Operating
Instructions
HRS-300
300mm Triple
Grating
Imaging
Spectrograph
and Scanning Monochromator
HRS-300 MANUAL - PRELIMINARY
Question and Answer IconNeed help?

Do you have a question about the Princeton Instruments HRS-300 and is the answer not in the manual?

Princeton Instruments HRS-300 Specifications

General IconGeneral
BrandPrinceton Instruments
ModelHRS-300
CategoryMeasuring Instruments
LanguageEnglish

Summary

HRS-300 Features

AccuDrive Scan System

High accuracy and repeatability of direct-drive wavelength scanning system.

Interchangeable Triple-Grating Turrets

Allows up to nine gratings for optimized system performance and self-alignment.

ResXtreme Spectral Deconvolution

Improves spectral resolution, intensity, and data consistency by up to 60%.

IntelliCal Calibration System

Push-button wavelength calibration for up to 10x greater accuracy.

SpectraPro HRS-300 Specifications

Spectral Resolution and Dispersion

PMT: 0.09 nm, CCD: 0.10 nm. Dispersion: 2.38 nm/mm.

Wavelength Accuracy and Reproducibility

Accuracy: +/-0.2 nm, Reproducibility: Within 0.004 nm.

Configurations

HRS-300 Setup

Unpacking and Inspection

Carefully unpack and examine the HRS-300 and accessories.

Connecting to a Computer

Control via USB or RS232 connection for wavelength scanning and grating control.

Mounting Accessories

General procedure for mounting PI SpectraPro accessories to slit assemblies.

Mounting Focal Plane Detectors

Procedure for mounting array detectors (CCDs, etc.) to the HRS-300 using Spec-Mount.

Model 716 Bilateral Slit: Width Adjustments

How to adjust slit width using the micrometer knob from 0.010 mm to 3 mm.

HRS-300 Operation

Initialization

System initialization upon power-up to set wavelength, grating, and turret reference.

Operating Using a Computer

Control via terminal emulation, USB, or RS232 using command set.

Focusing and Alignment of Array Detectors

Procedure to align and focus the array detector to the HRS-300 optical system.

Appendix 4: Gratings and Accessories

Light Sources

IntelliCal AE Light Source

USB-powered AE source for wavelength calibration with Hg and Ne-Ar lamps.

Light Input

Appendix 5: Certification and Warranty

Appendix 6: CE Declaration of Conformity