Installation and
Operation
Instructions

Questions and Answers

  • H
    Heather GrayAug 17, 2025
    What to do if my Pro-Fab Industries Furnace damper does not open?
    • J
      John MartinAug 17, 2025
      If the damper on your Pro-Fab Industries Furnace isn't opening, there could be several reasons. First, the high limit switches might be off because the water temperature is too high; in this case, wait for the water to cool down. Second, the circuit breaker may have disengaged because of creosote buildup, so clean the damper area and push the reset button on the breaker. Also, check your power supply. Finally, the damper solenoid might be defective and need replacement.
  • G
    Grant ReedAug 19, 2025
    Why is my Pro-Fab Industries Furnace circuit breaker disengaging?
    • K
      Katherine HowardAug 20, 2025
      If the circuit breaker in your Pro-Fab Industries Furnace is disengaging, it could be because the damper is sticking, causing the solenoid to overload. Try cleaning the damper thoroughly. Another reason might be a non-functioning blower (if you have a forced draft model), so clean and oil the blower.
  • C
    Christopher EvansAug 22, 2025
    What to do if hot water is not reaching the building from my Pro-Fab Industries Furnace?
    • S
      Sherri KaufmanAug 22, 2025
      If hot water isn't reaching the building from your Pro-Fab Industries Furnace, check the following: * Ensure the water level is adequate and fill the system to the proper level if it's low. * Verify that the water is circulating; if not, there may be no power to the pump or the pump is faulty and needs repair or replacement. * Check for air in the water lines and bleed the lines to release the water and reprime the circulating pump.
  • A
    Amanda MartinezAug 26, 2025
    What to do if my Pro-Fab Industries Furnace overheats and boils?
    • E
      Edwin NewtonAug 26, 2025
      If your Pro-Fab Industries Furnace is overheating and boiling, make sure the main door is closed. Also, check the main door and ash tray gaskets for leaks and replace them or adjust the latches and/or hinges as needed.
  • S
    Stephen RamosAug 27, 2025
    Why is there extensive condensation and creosote buildup in my Pro-Fab Industries Furnace?
    • K
      kristen97Aug 28, 2025
      Extensive condensation and creosote buildup in your Pro-Fab Industries Furnace can occur if the differential on the aquastat isn't large enough, causing the unit to cut in too often; increase the differential settings. Also, using wet or poor-quality wood can cause this issue, so use dry, seasoned firewood only.
  • K
    kathryn31Aug 31, 2025
    What to do if the water overheated and boiled over in my Pro-Fab Industries Furnace?
    • R
      rodriguezronaldAug 31, 2025
      If the water in your Pro-Fab Industries Furnace overheated, boiled over, and now there's no power to the damper and blower, the High Limit Switch (snap disc) may have tripped the circuit. This switch is designed to reset automatically when the temperature drops to approximately 130°F (54°C), restoring power.
  • R
    ryan43Sep 2, 2025
    What to do if there is little or no draft in my Pro-Fab Industries Furnace?
    • C
      Christopher HernandezSep 2, 2025
      If there's little or no draft in your Pro-Fab Industries Furnace, it could be because the furnace is cold. Start a small fire with dry kindling before reloading the furnace with firewood. Also, the chimney might be plugged, so clean it regularly.
  • W
    William WilliamsSep 5, 2025
    What to do if the demand for heat is on but no power is coming to the damper in my Pro-Fab Industries Furnace?
    • K
      Kimberly SmithSep 5, 2025
      If the demand for heat is on with sufficient wood, but no power is coming to the damper and blower in your Pro-Fab Industries Furnace, the damper lid may be stuck, causing the Reset Switch to pop out. Loosen the damper lid and push in the reset button.
  • M
    Michael SimmonsSep 7, 2025
    Why is my Pro-Fab Industries Furnace solenoid rattling during operation?
    • S
      Scott SchwartzSep 7, 2025
      If the solenoid is rattling during operation in your Pro-Fab Industries Furnace, the alignment between the solenoid and the lift tab might be off. Loosen all four adjustment screws and realign the solenoid until it operates smoothly.
  • B
    briankellySep 12, 2025
    Why is my Pro-Fab Industries Furnace ash tray sticking?
    • G
      Gregory RuizSep 12, 2025
      If the ash tray in your Pro-Fab Industries Furnace is sticking, it's likely due to creosote or condensation buildup. Oil the drawer slides and edges as required and remove the tray more often.