Oilless, Single Stage, Direct Drive, Electric Air Compressors
200-2705 (E103525)_ Rev A_7-08
WARNING: Read and understand all safety precautions in this manual before operating. Failure to comply with
instructions in this manual could result in personal injury, property damage, and/or voiding of your warranty. The
manufacturer WILL NOT be liable for any damage because of failure to follow these instructions.
Specification Chart
Questions? See back page.
?
Product style and configuration may
vary.
MODEL NO.
RUNNING
H.P.
(CV)
TANK CAPACITY
GALLONS
VOLTAGE/AMPS/
PHASE
KICK-IN
PRESSURE
KICK-OUT
PRESSURE
VPF1080318 1.0 3 (11,4) 120/12/1
95
(6,55 bar)
125
(8,62 bar)

Questions and Answers

  • G
    Gerald MartinJul 30, 2025
    What to do if the pressure relief valve opens on my Pro Force Air Compressor?
    • D
      Danielle KnightJul 30, 2025
      The pressure relief valve on your Pro Force Air Compressor might open because the tank pressure has exceeded the normal operating pressure or because the pressure switch is stuck. In both cases, you should replace the pressure switch.
  • S
    Stephanie GonzalezAug 13, 2025
    How to fix air leaks from the regulator on a Pro Force Air Compressor?
    • M
      Mr. Christopher GutierrezAug 14, 2025
      If air leaks from the regulator or it does not regulate pressure on your Pro Force Air Compressor, it is likely due to dirty or damaged internal parts. You should replace the regulator or its internal parts.
  • P
    pcampbellAug 20, 2025
    What to do if the pressure drops when using an accessory with my Pro Force Air Compressor?
    • B
      boonetravisAug 20, 2025
      The regulated pressure gauge reading on your Pro Force Air Compressor may drop when an air accessory is being used, which is normal. If the pressure drops too low, adjust the regulator while the accessory is in use. Also, check the air requirements of the accessory. If they exceed what the compressor provides, you may need a larger compressor.
  • E
    Evelyn MayNov 5, 2025
    Why won't the motor run on my Pro Force Air Compressor?
    • M
      Marvin CooperNov 5, 2025
      If the motor of your Pro Force Air Compressor won't run, several factors could be at play. If the tank pressure is too high, the motor will start automatically when it drops. If the motor overload protection has tripped, allow the motor to cool off to reset. Check and replace any blown fuses or reset tripped circuit breakers, ensuring replacements match the specified rating. Inspect the check valve for blockage, cleaning or replacing as needed. For a stuck pressure bleeder valve, move the pressure switch lever to the OFF position before restarting; replace the bleeder valve if it remains stuck. Confirm the cord's wire gauge and extension cord length are correct. For loose electrical connections, a defective capacitor or motor, or paint spray on internal motor parts, contact an authorized s...

Summary

Specification Chart

Safety Guidelines

Overview

Basic Air Compressor Components

Details the main parts of the air compressor, including motor, pump, pressure switch, and tank.

Assembly

Assembling the Compressor

Provides step-by-step instructions for unpacking, inspecting, and positioning the air compressor for use.

Compressor Controls

Electrical Power Requirements

Electrical Wiring

Refers to the unit's serial label for voltage and amperage requirements.

Extension Cords

Advises against using extension cords, but provides guidelines if one is necessary.

Grounding Instructions

Explains the importance of grounding and proper plug usage to prevent electric shock.

Operating Instructions

Daily Startup

Step-by-step guide for starting the air compressor, including safety warnings and pressure adjustment.

Shutdown

Instructions for safely turning off the compressor, unplugging, and relieving pressure.

Maintenance

Draining the Tank

Explains the daily procedure for draining condensation to prevent tank corrosion and freezing.

Parts List

Maintenance

Checking the Relief Valve

Daily procedure to test the relief valve's functionality and clear obstructions.

Testing for Leaks

Method for checking connections for leaks using soapy water and addressing any found.

Storage

Guidelines for cleaning and storing the compressor for prolonged periods to protect it.

Service Interval

Lists periodic maintenance tasks and their recommended frequency (e.g., daily).

Troubleshooting Chart

Parts and Service

Pro Force VPF1080318 Specifications

General IconGeneral
BrandPro Force
ModelVPF1080318
CategoryAir Compressor
LanguageEnglish