FAN
ON AUTO
SYSTEM
COOL OFF HEAT
Installation Manual
Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Heat Only Systems - Floor or Wall Furnace
Cool Only
Millivolt
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Power Type
Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with
Battery Backup
Table of Contents
Specications
Installation Tips
Thermostat Quick Reference
Wiring
Wiring Diagrams
Technician Setup
Page
A trained, experienced
technician must install this
product.
Carefully read these
instructions. You could damage
this product or cause a
hazardous condition if you fail
to follow these instructions.
Una version en español de este
manual se puede descargar en
la pagina web de la compañia.
Rev. 1809
U.S. Registered Trademark. Patents pending
Copyright 2018 All Rights Reserved.
Specications
The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)
The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)
Swing (cycle rate or dierential) ...... Heating is adjustable from 0.2˚ to 2.0˚
Cooling is adjustable from 0.2˚ to 2.0˚
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz
for hardwire
Battery power from 2 AA Alkaline
batteries
Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)
Operating humidity .............................. 90% non-condensing maximum
Dimensions of thermostat ................. 4.7”W x 4.4”H x 0.8”D
Mount Thermostat
Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.
Battery Installation
Battery installation is recommended even if thermostat is hardwired
(C terminal connected). When thermostat is hardwired and batteries
are installed, the thermostat will activate a compressor delay of 5
minutes when the thermostat detects a power outage from the
hardwired power supply.
Important:
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries
do not guarantee a 1-year life span.
Insert 2 AA
Alkaline batteries
(included). High
quality alkaline
batteries are
recommended.
Simple
operating
instructions
are found
on the back
of the
battery
door.
Gas or Electric Setup
Fan Operation Switch
Installation Tips
2-3
4
5
6
7-8
1
Installation Tips Thermostat Quick Reference
Getting to know your thermostat
Glow in the dark light button
Fan switch
System switch
Easy change battery door
Temperature setpoint buttons
LCD
The low battery indicator is displayed when the
AA battery power is low. If the user fails to
replace the battery within 21 days, the screen
will only show the low battery indicator but
maintain all functionality. If the user fails to
replace the batteries after an additional 21 days
(days 22-42 since rst “low battery display) the
setpoints will change to 55˚F (Heating) and 85˚F
(Cooling). If the user adjusts the setpoint away
from either of these, it will hold for 4 hours
then return to either 55˚F or 85˚F. After day 63
the batteries must be replaced immediately to
avoid freezing or overheating because the
thermostat will shut the unit o until the
batteries are changed.
Important
Removing The Private
Label Badge
About The Badge
All of our thermostats use the same universal magnetic badge. Visit the
company website to learn more about our free private label program.
=
88
Room Temperature
o
88
Set At
C
COOL ON
HEAT ON
F
LOW
Displays the
selected setpoint
temperature.
System Operation
Indicators:
The COOL ON, HEAT
ON or icon will
display when the
COOL, HEAT, or
(fan) is on.
NOTE: The
compressor
delay feature is active
if these icons are
ashing. The
compressor will not
turn on until the 5
minute delay has
elapsed.
Low Battery Indicator:
Replace batteries when
indicator is shown.
Indicates the current
room temperature.
Magnet in door
Subbase Installation
The thermostat should be installed approximately 4 to 5 feet above the
oor. Select an area with average temperature and good air circulation.
• Close to hot or cold air ducts
That are in direct sunlight
With an outside wall behind
the thermostat
• In areas that do not require
conditioning
Where there are dead spots
or drafts
(in corners or behind doors)
Where there might be
concealed chimneys or
pipes
Wall Locations
Vertical Mount
Horizontal Mount
For vertical mount put one screw on the top
and one screw on the bottom.
For horizontal mount put one screw on the
left and one screw on the right.
All of our products are mercury free.
However, if the product you are
replacing contains mercury, dispose of
it properly. Your local waste
management authority can give you
instructions on recycling and proper
disposal.
Pick an installation location that is easy for
the user to access. The temperature of the
location should be representative of the
building.
Installation Tip
Mercury Notice
Do not install
thermostat in locations:
Failure to disconnect the power before
beginning to install this product can
cause electrical shock or equipment
damage.
Installation Tip:
Electrical Hazard
Use the bevel on lower ridge
Gas: For systems that control the fan
during a call for heat, put the fan
operation switch to the GAS position.
Electric: For systems that do not
control the fan during a call for heat,
put the fan operation switch tothe
ELECTRIC position.
T701
Pro1 Technologies
Toll Free: 888-776-1427
Web: www.pro1iaq.com
Hours of Operation: M-F 9AM - 6PM Eastern
P.O. Box 3377
Springeld, MO 65808-3377
FAN
ON AUTO
SYSTEM
COOL OFF HEAT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pro T701 and is the answer not in the manual?

Pro T701 Specifications

General IconGeneral
Stages1 Heat/1 Cool
Programmability7-Day Programmable
Hold FunctionYes
Backlit DisplayYes
TypeProgrammable
Power SourceBattery
DisplayDigital
Display TypeLCD
CompatibilitySingle Stage HVAC Systems