4
PD2011
-9043-03
2 Year Guarantee
This guarantee covers failure of your PROcepon product resulng from manufacturing defect within a
period of 2 years from the date of supply to the end-user. This guarantee does not cover damage to the
product caused by abuse, tampering, defecve installaon or natural causes such as lightning discharge.
Repair or aempted repair, other than by the manufacturer, will render this guarantee void. This
guarantee does not aect a consumer's statutory rights.
Performance data given are typical unless otherwise stated. We reserve the right to change
product designs and specicaons without prior noce.
EU Declaraon of Conformity
Blake UK hereby declares that the radio equipment type PROAMP24, PROAMP24R, PROAMP26,
PROAMP26R, PROAMP28 and PROAMP28R are in compliance with Direcve 2014/53/EU.
The full text of the EU declaraon of conformity is available at the following internet
address: www.blake-uk.com/DoC
Other Ranges of Products & Services from Blake UK, PROcepon & CappSure...
Website: www.procepon.co.uk
Email: support@procepon.co.uk
©Blake-UK 2018 All rights reserved E&OE Product Specicaon may be Changed without Prior Noce
TV, Wi-Fi & 4G Aerials www.blake-uk.com/aerials
Brackets & Installaon Equipment www.blake-uk.com/bracketspoles
AV TV Wall Mounts www.blake-uk.com/tvbrackets
CappSure Wi-Fi IP Cameras www.blake-uk.com/cappsure
Coaxial Connectors & Adaptors www.blake-uk.com/procon
RF Signal Distribuon www.blake-uk.com/rfsignal
HDMI Signal Distribuon www.blake-uk.com/hdmi
LTE Filtering Products www.blake-uk.com/lte
Satellite Mounts www.blake-uk.com/satmount
Bespoke Manufacturing www.blake-uk.com/bespoke
UK R&D www.blake-uk.com/researchdevelop
Related Products: Link to Website:
Setback Ampliers: 1 & 2-Way FM/DAB/UHF Ampliers without IR www.blake-uk.com/amp
PROAMP12R: 2-Way Setback Amplier with IR www.blake-uk.com/ampr
PROSAT1EYE: IR Control Eye 'Magic Eye www.blake-uk.com/eye
PROLINK22: Flexible 'I/O Link' RF Modulator for Sky www.blake-uk.com/prolink22
PROCON01: F Male Twist-On +O-Ring - RG6/100 www.blake-uk.com/procon01
PROCON02: F Male Twist-On +O-Ring Black - RG6/100 www.blake-uk.com/procon02
PROCON12: F Male Crimp-On Black - RG6/100 www.blake-uk.com/procon12
PROCON22: F Male Snap Seal / Compression - RG6/100 www.blake-uk.com/procon22
1
VHF/UHF Distribuon Ampliers Instrucon Manual
PROAMP24-26-28 www.blake-uk.com/distamp
PROAMP24R-26R-28R www.blake-uk.com/ampr
These ampliers are ideal for use in small digital and analogue recepon and distribuon systems. All
MK3 products feature a ltered dual-band VHF input which accepts signals in both Bands II and III,
allowing use for Band III DAB or TV, as well as for FM radio.
All these ampliers are compliant with the Radio Equipment Direcve 2014/53/EU and meet the
harmonised standard EN 303 354 for Class 0. As such they work on ALL current UK DTT channels
including channel 60, are resilient to interference and overloading, and cope with mulple carriers. In
cases of strong LTE interference a separate 4G lter should be ed. These are supplied free by at800,
or higher performance models can be purchased from www.blake-uk.com. (To pass channels up to and
including channel 59 use proLTE1/59, or if channels 58 and 59 are not required, use proLTE1/57).
Features: (Whole Range)
Separate VHF and UHF inputs.
New dual-band VHF input for Band II FM radio and Band III DAB or TV.
4-, 6- and 8-way versions available.
Low noise gure and high output capability.
New equipotenal bonding terminal added on Mk 3 versions.
Channels 61-68 can be used for locally modulated signals.
Features: (PROAMP24, 26 & 28)
Tradional mul-way aerial signal ampliers.
Line power available at UHF input 12V at up to 100 mA.
Higher-gain FULL output on 6- and 8-way versions allows expansion beyond eight points.
IEC connectors.
Features: (PROAMP24R, 26R & 28R)
7 MHz return path for Sky* infrared remote control systems.
Built-in power for IR eyes on all outputs.
F connectors.
Note: R versions do not have input line-power capability or FULL outputs.
Fixing:
Fix the amplier to a sound vercal surface such as a wall, skirng board or equipment mounng board.
Venlaon gaps of at least 50 mm should be le around the front and sides of the unit. More clearance
will be required below the unit to allow access for the signal cables.
Being fully screened, the amplier will not be aected by proximity to an antenna. However clearance
of not less than 300 mm from the nearest part of the antenna should be observed to avoid degrading
the antenna's performance. Manufacturer's instrucons regarding roung of the cable from the
antenna terminal box must be followed if provided.
Do not leave the amplier resng on a carpet or install it where it may become smothered with curtains
or other so furnishing fabrics. When installing the amplier unit in a roof space ensure that it will not
come into contact with thermal insulaon material.
Signal Connecons:
To preserve RF screening integrity the signal connecons to the amplier should be made using good
quality coaxial cable and connectors. This is parcularly important with digital terrestrial TV (DTT) to
minimise the ingress of impulsive electrical interference from home appliances.
The use of cable benchmarked under the CAI scheme is recommended.
Ampliers PROAMP24, ‘26 and ‘28 require IEC connectors (IEC 60169-2).
Ampliers PROAMP24R, ‘26R and ‘28R requires Type-F connectors (IEC 60169-24).

Other manuals for PROception proAMP24

Question and Answer IconNeed help?

Do you have a question about the PROception proAMP24 and is the answer not in the manual?

Summary

EU Declaration of Conformity

2 Year Guarantee

Important

FULL Output Termination

Ensures proper termination of the FULL output for optimal performance and to avoid affecting other outputs.

Using Remote Control

PROception Remote Control Compatibility

Explains compatibility with PROception PROSAT1EYE and other Sky* remote control extenders for remote viewing.

System Equipotential Bonding

BS EN 60728-11 Compliance

Details requirements for earthed equipotential bonding in distribution systems, recommended for all installations.

Safety Instructions

Overheating Precautions

Advises on ventilation clearances and avoiding smothering to prevent overheating of the amplifier unit.

Water and Fire Risk Prevention

Warns against water exposure and naked flames, stating the appliance is for indoor use only.

Mains Plug and Supply Disconnection

Covers fuse replacement, plug changing, and ensuring accessibility of disconnection means.

Overview

The PROception VHF/UHF Distribution Amplifiers are designed for use in small digital and analogue reception and distribution systems. These MK3 products feature a filtered dual-band VHF input, accepting signals in both Bands II and III, making them suitable for Band III DAB or TV, as well as FM radio. All amplifiers comply with the Radio Equipment Directive 2014/53/EU and meet the harmonised standard EN 303 354 for Class 0. They are designed to work on all current UK DTT channels, including channel 60, and are resilient to interference and overloading, coping with multiple carriers. In cases of strong LTE interference, a separate 4G filter should be fitted. These filters are supplied free by at800, or higher performance models can be purchased from www.blake-uk.com. For channels up to and including channel 59, proLTE1/59 should be used, or if channels 58 and 59 are not required, proLTE1/57.

General Features (Whole Range):

  • Separate VHF and UHF inputs.
  • New dual-band VHF input for Band II FM radio and Band III DAB or TV.
  • Available in 4-, 6- and 8-way versions.
  • Low noise figure and high output capability.
  • New equipotential bonding terminal added on Mk 3 versions.
  • Channels 61-68 can be used for locally modulated signals.

Features (PROAMP24, 26 & 28):

  • Traditional multi-way aerial signal amplifiers.
  • Line power available at UHF input: 12V at up to 100 mA.
  • Higher-gain FULL output on 6- and 8-way versions allows expansion beyond eight points.
  • IEC connectors.

Features (PROAMP24R, 26R & 28R):

  • 7 MHz return path for Sky* infrared remote control systems.
  • Built-in power for IR eyes on all outputs.
  • F connectors.
  • Note: R versions do not have input line-power capability or FULL outputs.

Technical Specifications:

Features PROAMP24 & 24R PROAMP26 & 26R PROAMP28 & 28R
Number of outputs 4 6 8
Signal frequency range (VHF) 87.5-108MHz & 174-230MHz 87.5-108MHz & 174-230MHz 87.5-108MHz & 174-230MHz
Signal frequency range (UHF) 470-862MHz 470-862MHz 470-862MHz
Noise figure 3dB 3dB 3dB
Gain to each output (except FULL) 7dB 5dB 5dB
Gain to each FULL output - 16dB 16dB
Output capability (see note below) 86dBμV 82dBμV 82dBμV
IR receiver ('eye') line-power 9V@15mA (s/c protected) present at all outputs ('R' versions only)
Signal connector type 'IEC' (IEC 60169-2)
Signal connector type ('R' versions) 'F' (IEC 60169-24)
Mains power requirement 230V 50Hz@2W (8 VA)
Operating temperature range -10 - +40 °C
  • Output Capability Note: Given for 5 analogue TV channels plus up to 6 DTT multiplexes at <-14dB relative level (VHF FM and DAB radio signal should not exceed -10dB relative to analogue TV).
  • Dual-band VHF input: The VHF input accepts Band II FM radio signals and/or DAB or TV signals in Band III. Separate bandpass circuits in the amplifier provide filtering outside and between these bands. For multiple aerial connections, a separate diplexer such as the PROception proCOM31T should be used.

Usage Features:

  • Remote Control (R versions): Compatible with PROception PROSAT1EYE and other Sky* remote control extenders. To use this feature, the amplifier input must be fed directly from the RF OUT-2 connector or I/O port of the Sky receiver. The amplifier provides 9 V DC power for up to two remote receiver eyes. Some Sky receivers require their RFOUT-2 power option to be enabled (SERVICES, 4, 0, 1, SELECT, then SECOND OUTLET POWER SUPPLY option, set to ON, SAVE SETTINGS and BACK UP). DC continuity must be maintained through coaxial cabling between the amplifier output(s) and the IR receiver equipment. Isolated outlet plates cannot be used in remote rooms. Connections must be securely clamped, crimped, or soldered. When troubleshooting, check for approximately 9 V DC on the cable in the remote room.
  • FULL Output: The FULL output (where fitted) allows additional outlets to be fed via an external passive network. This network should present a good 75 Ω load to the amplifier. The terminator plug supplied must always be fitted if the FULL output is not used.
  • System Equipotential Bonding: For distribution systems supplying signals to more than one household, compliance with BS EN 60728-11 (earthed equipotential bonding) is required. Although not mandatory for single households, it is strongly recommended for all installations. All PROAMP Mk 3s include a bonding terminal. A 4 mm² bonding conductor should be connected to the main earth terminal of the electrical installation. Bonding can be achieved using PROception PROBAR5 or 8 equipotential bonding bar.

Installation and Maintenance Features:

  • Fixing: Fix the amplifier to a sound vertical surface (wall, skirting board, or equipment mounting board). Leave ventilation gaps of at least 50 mm around the front and sides. More clearance is needed below for signal cables. The amplifier is fully screened, but a clearance of not less than 300 mm from the nearest part of the antenna should be observed to avoid degrading antenna performance. Follow manufacturer's instructions for cable routing from the antenna terminal box.
  • Placement Restrictions: Do not leave the amplifier resting on a carpet or install it where it may become smothered by curtains or other soft furnishing fabrics. In a roof space, ensure it does not contact thermal insulation material.
  • Signal Connections: Use good quality coaxial cable and connectors to preserve RF screening integrity, especially for digital terrestrial TV (DTT) to minimise ingress of impulsive electrical interference. The use of cable benchmarked under the CAI scheme is recommended. PROAMP24, '26 and '28 require IEC connectors (IEC 60169-2). PROAMP24R, '26R and '28R require Type-F connectors (IEC 60169-24). For both connector types, crimp connectors used according to manufacturer instructions will yield the best results. Sound braid connections are crucial. F connectors should be tightened with a spanner.
  • Overheating: Intended for use in moderate climates only, not tropical regions. Observe recommended ventilation clearances and precautions to prevent overheating. Do not fix where it is likely to be smothered by soft furnishing fabrics or thermal insulation material in a roof space or building void. Mains powered equipment should not be left resting on a carpet.
  • Water and Fire Risks: The appliance is not waterproof and is for indoor use only. Do not fix where it could be exposed to dripping or splashing water. Do not place objects containing liquids on or near the appliance. To prevent fire, do not place objects with a naked flame on or near the appliance or its associated wiring.
  • Mains Plug and Disconnection: Supplied with a standard fused plug. If unsuitable, refer to instructions for changing the plug. If changing the fuse, use a 3 Amp fuse to BS 1362 with ASTA or BSI approval mark. Always replace the plastic fuse carrier when renewing the fuse. The plug (or other means of disconnection) should remain readily accessible. The LED power indicator should not be regarded as reliable indication of supply disconnection.
  • Changing the Plug: If the fitted mains plug is unsuitable, cut it off and fit a new plug. Follow instructions supplied with the new plug. The brown wire connects to the live (L) terminal, and the blue wire to the neutral (N) terminal. Neither wire connects to the earth (E) terminal (appliance does not require an earth connection). Ensure the cord grip is correctly used. If the new plug is fused, the fuse should be rated at not more than 3 Amp. The old plug should be destroyed immediately as it is dangerous if plugged into a live socket.

Guarantee:

A 2-year guarantee covers manufacturing defects from the date of supply to the end-user. It does not cover damage from abuse, tampering, defective installation, or natural causes (e.g., lightning discharge). Repair or attempted repair by anyone other than the manufacturer voids the guarantee. This guarantee does not affect consumer statutory rights. Performance data is typical unless stated otherwise. Product designs and specifications may change without prior notice.