Ag.Dimitriou 286A ,173 42 Agios Dimitrios
Τηλ. Κέντρο: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
3029
Control panel for rolling shutters up to 1200watt
AUTO-CLOSE FUNCTION
OFF: No auto close
ON: Auto-close. Embedded auto close function. Works with the photocell.
When the gate opens and there is no access (no obstacle detection from the
photocell), the A/C time is 120 seconds (the gate will close after 120
seconds). If there is access and obstacle detection from the photocell, then
the A/C time is 10 seconds (the A/C timer counts 10 seconds after the
photocell is free and then the gate will automatically close). The second time
of A/C can be changed (follow the below instructions).
PHOTOCELLS
OFF: NO photocells.
ON: Photocells. The power supply of the photocell 24VAC in terminals
13&14 and COM & NC of the photocell in terminals 8 & 9.
MOTOR REVERSION
OFF/ON: The first move of the motor needs to be opening, after the power
of control panel. When the first move is closure, switch the dipswitch 7 to
the opposite position.
Covering distance: from 30 – 100 μ. depends on external conditions.
Check all connections. Check the terminal switches of the motor. The BLUE/GREY (common) motor wire is connected in terminal 4. Earth motor wire is not
connected in the control panel.
PHOTOCELL
TRANSFORMER
V - 1,5VA12
TRANSFORMER
24V - 1,5VA
CODE
ΧΡΟΝ ΟΣ
REEIVER
PROGRAMMS
1 2 3 4 5 6 7 8
ON
FUSE 5Α
RECEIVER RF
FLASH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
M
L I V E
NEUTRAL
COMMON
START/STOP
PHOTO
ANTENNA
OPEN
CLOSE
230VAC
24VAC
60mA
COMMON
230V