Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
3029
Control panel for rolling shutters up to 1200watt
Code
Frequency
Codification
Terminal
Switches
Photocell
s
Auto close
Light
230V
Motor
torque
Slow
move
Reverse
move
Memory
PSR/PTR - 3029
433,92/868,3
Keeloq
Rolling
YES
YES
YES
YES
NO
NO
YES
300
PS-3029
433,92
Standard
YES
YES
YES
YES
NO
NO
YES
300
PN-3029
433,92
Profelmnet
Rolling
YES
YES
YES
YES
NO
NO
YES
300
Covering distance: from 30 100 μ. depends on external
conditions.
Νο
Function description
1
Not used
2
Not used
3
AUTO-CLOSE FUNCTION
OFF: No auto close
ON: Auto-close. Embedded auto close function. Works with
the photocell. When the gate opens and there is no access
(no obstacle detection from the photocell), the A/C time is
120 seconds (the gate will close after 120 seconds). If there is
access and obstacle detection from the photocell, then the
A/C time is 10 seconds (the A/C timer counts 10 seconds after
the photocell is free and then the gate will automatically
close). The second time of A/C can be changed (follow the
below instructions).
4
Not used.
5
PHOTOCELLS
OFF: NO photocells.
ON: Photocells. The power supply of the photocell 24VAC in
terminals 13&14 and COM & NC of the photocell in terminals
8 & 9.
6
Not used
7
MOTOR REVERSION
OFF/ON: The first move of the motor needs to be opening,
after the power of control panel. When the first move is
closure, switch the dipswitch 7 to the opposite position.
8
Not used
Check all connections. Check the terminal switches of the motor. The BLUE/GREY (common) motor wire is connected in terminal 4. Earth motor
wire is not connected in the control panel.
PHOTOCELL
TRANSFORMER
V - 1,5VA12
TRANSFORMER
24V - 1,5VA
CODE
ΧΡΟΝΟΣ
REEIVER
PROGRAMMS
1 2 3 4 5 6 7 8
ON
FU
SE 5Α
R
ECEIVER
RF
FLASH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
M
L I V E
NEUTRAL
COM
M
ON
START/STOP
PHOTO
ANTENNA
OPEN
CLOSE
230VAC
24VAC
60mA
COMMON
230V

Other manuals for Profelmnet 3029

Question and Answer IconNeed help?

Do you have a question about the Profelmnet 3029 and is the answer not in the manual?

Summary

Control Panel Overview

Unused Function 1

This function slot is currently not assigned for use.

Unused Function 2

This function slot is currently not assigned for use.

Auto-Close Function

Configures automatic closing of the rolling shutter based on time and photocell detection.

Unused Function 4

This function slot is currently not assigned for use.

Photocell Integration

Enables or disables photocell functionality and specifies connection terminals.

Unused Function 6

This function slot is currently not assigned for use.

Motor Reversion Setting

Sets the initial motor movement direction (opening or closing) after power-up.

Unused Function 8

This function slot is currently not assigned for use.

Functions and Connections

230 V Power Supply

Instructions for connecting the 230Vac power supply to the control panel.

Clear Transmitter Memory

Procedure to erase all stored transmitter codes from the control panel memory.

Add Transmitter (Panel Button)

Process for programming new transmitters using the control panel's CODE button.

Adjust Working Time

Method to set the operational duration for gate movement.

Add Transmitter (Remote)

Procedure to program new transmitters using an existing remote control.

Pedestrian Function

Enables partial gate opening for pedestrian access, requiring photocells.

Photocell Connection

Details on wiring photocells to the control panel for safety and automatic closing.

Photocell Operation

Describes how the gate reacts to photocell beam interruptions during closing.

Blinker Light Function

Explains the 230V/10W output for indicator lights and its operational duration.

Adjusting Auto Close Time

Configuration of the automatic closing delay for the gate.

Indication Light LEDs

Overview of indicator LEDs that display control panel functions.

Reset Automation

Procedure to reset the control panel in case of malfunction by removing power.

Overview

The Profelmnet 3029 is a control panel designed for rolling shutters up to 1200 watts. It supports various codification types including Keeloq Rolling, Standard, and Profelmnet Rolling, operating on frequencies of 433.92 MHz and 868.3 MHz. The panel offers a range of features such as terminal switches, photocell support, external button connectivity, auto-close functionality, light control, motor torque adjustment, slow move, reverse move, and memory for up to 300 transmitters.

Technical Specifications:

  • Power Supply: 230VAC, with a 12V - 1.5VA transformer and a 24V - 1.5VA transformer.
  • Motor Output: 230VAC.
  • Photocell Power Supply: 24VAC, 60mA.
  • Blinker Light Output: 230V / 10W.
  • Transmitter Memory: Up to 300 transmitters.
  • Working Time Adjustment: 1-180 seconds.
  • Auto-Close Time Adjustment: 1-120 seconds.
  • Frequency: 433.92 MHz (for PS-3029 and PN-3029) and 433.92/868.3 MHz (for PSR/PTR-3029).

Function Description:

  • Auto-Close Function: This feature allows the gate to close automatically after a set period. When the gate opens and there is no obstacle detected by the photocell, the auto-close time is 120 seconds. If an obstacle is detected, the timer resets, and the gate will close 10 seconds after the photocell beam is clear. The second auto-close time (10 seconds) can be adjusted. To enable this, dipswitch 3 must be in the ON position.
  • Photocells: When enabled (dipswitch 5 ON), photocells prevent the gate from closing if an obstacle is in the beam. If the beam is cut during closing, the door stops immediately and re-opens. The photocell power supply (24VAC) connects to terminals 13 & 14, and the COM & NC contacts connect to terminals 8 & 9.
  • Motor Reversion: Dipswitch 7 controls the initial motor movement. If the first movement after power-up is closure instead of opening, switch dipswitch 7 to the opposite position.
  • Working Time Adjustment: The motor's working time can be adjusted from 1 to 180 seconds. To set this, fully close the gate, then press and hold the "TIME" button on the control panel until the gate reaches its fully open position. Release the button to save the setting.
  • Blinker Light Function: The control panel provides a permanent 230V / 10W output for a blinker light, connected to terminals 1 & 3. The light operates as long as the gate is moving. If a longer flashing time is desired (e.g., 100 seconds), program the working time of the control panel to 100 seconds.
  • Pedestrian Function: When photocells are installed, this function allows the gate to open for a short period when a pedestrian traverses it, then automatically close. The closing time is the same as the second auto-close time.

Usage Features:

  • Clear Memory: To clear all stored transmitters, press and hold the "CODE" button on the control panel. The red indication light will turn ON, then OFF, indicating the memory is clear.
  • Adding a New Transmitter (Control Panel Button): Press the "CODE" button; the red indication light will turn ON. Release it, and within 3 seconds, press the desired channel button on the new transmitter. The red light will blink and then turn OFF, confirming the transmitter is saved. Up to 300 transmitters can be added.
  • Adding a New Transmitter (Remotely): With the motor fully closed or open, press a working transmitter button (already in memory) to start the motor. Keep it pressed until the motor stops. Release it, then immediately press the new transmitter button. The new transmitter is saved. This method can also be used to program multiple transmitters.
  • Indication LED Lights: Various LED lights on the control panel display the status and functions of the photocells.
  • Covering Distance: The effective range of the remote control is 30-100 meters, depending on external conditions.

Maintenance Features:

  • Reset Automation: In case of malfunction, disconnect the 230VAC power supply for 10 seconds, then reconnect and recheck the system.
  • Connections Check: Ensure all connections are secure. The BLUE/GREY (common) motor wire must be connected to terminal 4. The earth motor wire is not connected to the control panel.
  • Compatible Transmitters: Select transmitters compatible with the specific model of the control panel.

Profelmnet 3029 Specifications

General IconGeneral
BrandProfelmnet
Model3029
CategoryControl Panel
LanguageEnglish