Control panel for rolling shutters up to 1200watt
Code
Frequency
Codification
Terminal
Switches
Photocell
s
Auto close
Light
230V
Motor
torque
Slow
move
Reverse
move
Memory
PSR/PTR - 3029
433,92/868,3
Keeloq
Rolling
YES
YES
YES
YES
NO
NO
YES
300
PS-3029
433,92
Standard
YES
YES
YES
YES
NO
NO
YES
300
PN-3029
433,92
Profelmnet
Rolling
YES
YES
YES
YES
NO
NO
YES
300
Covering distance: from 30 100 μ. depends on external
conditions.
Νο
Function description
1
Not used
2
Not used
3
AUTO-CLOSE FUNCTION
OFF: No auto close
ON: Auto-close. Embedded auto close function. Works with
the photocell. When the gate opens and there is no access
(no obstacle detection from the photocell), the A/C time is
120 seconds (the gate will close after 120 seconds). If there is
access and obstacle detection from the photocell, then the
A/C time is 10 seconds (the A/C timer counts 10 seconds after
the photocell is free and then the gate will automatically
close). The second time of A/C can be changed (follow the
below instructions).
4
Not used.
5
PHOTOCELLS
OFF: NO photocells.
ON: Photocells. The power supply of the photocell 24VAC in
terminals 13&14 and COM & NC of the photocell in terminals
8 & 9.
6
Not used
7
MOTOR REVERSION
OFF/ON: The first move of the motor needs to be opening,
after the power of control panel. When the first move is
closure, switch the dipswitch 7 to the opposite position.
8
Not used
Check all connections. Check the terminal switches of the motor. The BLUE/GREY (common) motor wire is connected in terminal 4. Earth motor
wire is not connected in the control panel.
PHOTOCELL
TRANSFORMER
V - 1,5VA12
TRANSFORMER
24V - 1,5VA
CODE
ΧΡΟΝΟΣ
REEIVER
PROGRAMMS
1 2 3 4 5 6 7 8
ON
FU
SE 5Α
R
ECEIVER
RF
FLASH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
M
L I V E
NEUTRAL
COM
M
ON
START/STOP
PHOTO
ANTENNA
OPEN
CLOSE
230VAC
24VAC
60mA
COMMON
230V

Other manuals for Profelmnet 3029

Question and Answer IconNeed help?

Do you have a question about the Profelmnet 3029 and is the answer not in the manual?

Profelmnet 3029 Specifications

General IconGeneral
BrandProfelmnet
Model3029
CategoryControl Panel
LanguageEnglish

Summary

Control Panel Overview

Unused Function 1

This function slot is currently not assigned for use.

Unused Function 2

This function slot is currently not assigned for use.

Auto-Close Function

Configures automatic closing of the rolling shutter based on time and photocell detection.

Unused Function 4

This function slot is currently not assigned for use.

Photocell Integration

Enables or disables photocell functionality and specifies connection terminals.

Unused Function 6

This function slot is currently not assigned for use.

Motor Reversion Setting

Sets the initial motor movement direction (opening or closing) after power-up.

Unused Function 8

This function slot is currently not assigned for use.

Functions and Connections

230V Power Supply

Instructions for connecting the 230Vac power supply to the control panel.

Clear Transmitter Memory

Procedure to erase all stored transmitter codes from the control panel memory.

Add Transmitter (Panel Button)

Process for programming new transmitters using the control panel's CODE button.

Adjust Working Time

Method to set the operational duration for gate movement.

Add Transmitter (Remote)

Procedure to program new transmitters using an existing remote control.

Pedestrian Function

Enables partial gate opening for pedestrian access, requiring photocells.

Photocell Connection

Details on wiring photocells to the control panel for safety and automatic closing.

Photocell Operation

Describes how the gate reacts to photocell beam interruptions during closing.

Blinker Light Function

Explains the 230V/10W output for indicator lights and its operational duration.

Adjusting Auto Close Time

Configuration of the automatic closing delay for the gate.

Indication Light LEDs

Overview of indicator LEDs that display control panel functions.

Reset Automation

Procedure to reset the control panel in case of malfunction by removing power.