ELECTRONIC CONTROL PANEL
EN - English Page 12
11. Press the scroll
button again; the display will show
(only when the regeneration mode is set to Dlyd or
Dlyd/Immd):
Press the up
or down
button to set the reserve
capacity:
Variable: the reserve capacity is calculated
automatically, based on the registered daily water
usage.
Fxd: press the scroll
button again and press the
up
or down
button to set the reserve
capacity to a fixed amount.
12. Press the scroll
button again; the display will show:
Press the up
or down
button to set the function
of auxilliary contact 2:
Regen: aux. contact is powered during entire
regeneration (does not include refill and brine
preparation cycles!).
Chlor.Cell: aux. contact is powered at start of
brine draw/slow rinse cycle. Press the scroll
button again and press the up
or down
button to set the duration of activation of the
chlorination cell.
Maintenance: aux. contact is powered when
Maintenance Reminder is triggered.
Error: aux. contact is powered when timer failure
occurs.
13. Press the scroll
button again; the display will show:
Press the up
or down
button to save the
program into the NOVRAM® and exit the
programming level.