Menu Navigation – Neighboring rebar correction
Metric & Japanese units
ASTM units
Right Side Button
Navigate Right
Left Side Button
Navigate Left
Main Menu Screen
+
+
It compensates the influence of 1st and 2nd layer neighbor rebars (AI) or 1st layer
neighbor rebars only (NRC) on cover measurement of 1st layer rebars. If both a1 and
a2 spacings are entered, Φ1 ≤ Φ2 and Standard Range is set, then the Artificial
Intelligence is automatically applied. If only a1 spacing is entered or Φ1 > Φ2 or
Large/Spot Range is set, then the Neighboring Rebar Correction (only taking into
account 1st layer) is automatically applied.
The user can enter the spacing value manually or choose the Auto function, which
redirects to a Single-Line scan where the spacing is automatically measured and
averaged.
The rebar size measurement is anyway only corrected with NRC.
Further Information
NOTE!
This effect can be reduced by the neighboring bar correction
Any ferromagnetic material within the
sphere may have an influence on the
signal value (e.g. during a reset)