FUEL PUMP PRESSURE
CHECK AND SERVICE
Instructions
1. Disconnect power to heater.
2. Remove air compressor hose to ensure heater will not run in
full output during test.
3. Remove fuel outlet hose from fuel pump.
Figure A.
To avoid the risk of shock, ensure
to disconnect power to heater unit
during disassembly/reassembly.
WARNING
4. Remove ‘T’ fitting from test gauge PK0060.
3
2
AIR COMPRESSOR HOSE
FUEL OUTLET HOSE
4
TEST GUAGE
PK0060K
‘T’ FITTING
Figure B.
Fire Hazard. DO NOT place any
flammable items around the heater
and exhaust pipe.
WARNING
Copy Part# SB0062, Rev. B, 09/2014 Page 1 of 6
© 2011 Marine Canada Acquisition Inc. DBA SEASTAR SOLUTIONS 3831 No. 6 Road, Richmond, B.C. Canada V6V 1P6 Tel: 604.270.6899 Web: www.proheat.com