HOSE TO
NOZZLE AIR
INLET
DIGITAL
MANOMETER
PK0037
HOSE FROM COMPRESSOR
AIR PRESSURE SETTING
RECOMMENDATION
for
Sustained High Altitude Operations
Test Procedure
Requirements
Sustained operation and servicing of the X45 compressor above
4,000 ft (1219 m) requires the compressor setting be checked and/
or adjusted for proper combustion.
For sustained operation above 7000 feet (2134 m) the compressor
must be adjusted in order to maintain proper combustion.
1. Run heater until warm to the touch. This ensures the heater
components are up to normal operating temperature.
2. Switch heater off.
3. Connect Digital Manometer PK0037 (or analog gauge PK0060)
in-line as shown in figure A.
a) Basic Hand Tools.
b) Proheat Remote Start Switch (P/N 952925K).
c) Proheat Digital Manometer Test Gauge (P/N PK0037).
d) Or Proheat Analog Air Pressure Test Gauge (P/N PK0060).
If using PK0060, Analog air pressure
gauge, Calibrate gauge before each,
use refer to: www.proheat.com/PDFs/
990614.pdf
NOTICE
Remove Pressure Gauge when finished
with measuring & setting procedure.
NOTICE
4. Locate the rubber boot on the positive end of the ignition coil and
peel it back to expose the positive terminal.
Figure A. Digital Manometer PK0037.
Copy Part# SB0060, Rev. B, 08/2014 Page 1 of 3