Benämning
Art.no: XX-XXXX Model: XXXXX
Please read the entire instruction manual before use and save for future reference.
We apologise for any text or photo errors and any changes of technical data. If you have any questions con-
cerning technical problems please contact our Customer Service Department.
GREAT BRITAIN: For consumer contact, please visit www.clasohlson.co.uk and click on customer service.
Internet: www.clasohlson.co.uk
GREAT BRITAIN • CUSTOMER SERVICE tel: 020 8247 9300
e-mail: customerservice@clasohlson.co.uk internet: www.clasohlson.co.uk
1
2
3
4
5
6
7
8
9
10
20150701
Wireless indoor/
outdoor thermometer
Art.no 36-4741 Model YT6981
36-4744 YT6981 EX
Please read theentire instruction manual before using theproduct
and save it for future reference. Wereserve theright for any errors in
text or images and any necessary changes made to technical data.
If you have any questions regarding technical problems please
contact our customer services.
Product description
Main unit. Displays/monitors indoor temperature.
1 sensor (36-4744). Measurestheindoor/outdoor temperature
where it islocated.
Max 3 sensors can be connected.
Indoor temperature range: 0 to +50 °C
Outdoor temperature range: −30 to +70 °C
Memory for max-/min indoor/outdoor temperature readings.
Low battery indicator.
Buttons and functions
Main unit
CH button
Pressing [CH] will give you 4 options: Displaying temperature
readings from individual sensors on channel 1, 2 or 3 or
continuous display of all three channels. Depressuntil
thecircular icon appears to theleft of CH1 for continuous
display of all sensors.
Press again to deactivate continuous display.
Depress [CH] for three seconds to start theautomatic sensor scan.
Thescanning process lasts about 3 minutes.
MAX/MIN button
Press MAX/MIN once to view themin temperature.
Press again to display themax temperature.
Depress for 2 seconds to reset.
°C/°F button
Press to select between °C or °F.
Sensor
Open thesensor’s battery cover by
unscrewing its 4 retaining screws.
Insertbatteries according to themarkings in
thebattery compartment.
If several sensors are used, remove
thebattery covers on all of them and set their
channels using thechannel selector (11) to
1, 2 or 3.
TX button
Press [TX] when you desire to send thelatest reading to
themain unit.
Care and maintenance
Remove thebatteries if theproduct is not to be used for
alongtime.
Clean theappliance’s exterior using alightly moistened cloth.
Onlyuse mild detergents, never solvents or corrosive chemicals.
Disposal
Disposal of this product should be in accordance with local regulations.
Ifyou are unsure how to proceed, contact your local authority.
Specifications
Temperature range Approx. −30 to +70 °C
Frequency 433.92 MHz
Range approximately 25 m
The sensor transmits in 35 second intervals.
1. Wall bracket
2. Fold-out stand
3. [MAX/MIN] max-/min
temperature display.
4. [CH] Sensor channel
display selector, CH1,
CH2, CH3 or continuous
display. Sensorscan
control.
5. [°C/°F] Temperature unit
selector
6. Battery cover
Sensor
7. Wall bracket
8. Fold-out stand
9. [TX] Transmitter
10. Battery cover
retainingscrews
Operation
Main unit
Open themain unit’s battery cover by sliding
it straight down. Insertthebatteries according
to themarkings in thebattery compartment.
The main unit will display indoor temperature and
will automatically scan for asensor/s (the aerial
symbol will flash while scanning is in progress).
Thescanning process lasts about 3 minutes.
Display
The display shows theINDOOR TEMPERATURE on top and
theOUTDOOR TEMPERATURE underneath.
Under theOUTDOOR TEMPERATURE display will be
thechannel display: CH1, CH2 and CH3.
The display also has trend arrows which show trends for rising,
falling or stable temperature readings and has alow battery
indicator as well for both themain unit and sensor.
Points worth bearing in mind!
Other wireless equipment operating on the same frequency
band may reduce the range of the product.
The range of all wireless equipment is affected by obstacles
between the transmitter and the receiver (aconcrete wall
reduces the signal far more than a plasterboard partition,
forexample).
If you are having problems with the operation of
the system, try the following solutions
Switch off any other wireless equipment to check whether it
could be causing the problem.
Move the wireless equipment and/or reduce the distance,
and reduce thenumber of obstacles (walls, furniture, etc.)
between the transmitter andthe receiver.
Question and Answer IconNeed help?

Do you have a question about the prologue YT6981 and is the answer not in the manual?

prologue YT6981 Specifications

General IconGeneral
Brandprologue
ModelYT6981
CategoryThermometer
LanguageEnglish

Summary

Product Overview and Specifications

Product Description

Details the main unit and sensor capabilities, including temperature ranges and battery indicators.

Specifications

Lists technical details such as temperature range, frequency, and transmission range.

Device Operation and Controls

Main Unit Operation

Instructions for powering the main unit, scanning for sensors, and its initial display.

Sensor Setup and Function

Guidance on setting up the sensor, including battery insertion and channel selection.

Interactive Display and Buttons

Explains display features and the functions of CH, MAX/MIN, °C/°F, and TX buttons.

Maintenance and Disposal

Care and Maintenance

Recommendations for cleaning the appliance and long-term battery removal.

Disposal Instructions

Guidance on how to dispose of the product in accordance with local regulations.

Troubleshooting and Compliance

Points Worth Bearing in Mind

Notes on factors affecting wireless range and common operational issues.

Declaration of Conformity

Statement of compliance with essential requirements and provisions of relevant directives.