ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
iv. Diaphragm Polymer Pumps used on S & C Models:
Notes:
1. ProMinent – Gamma XL Solenoid Driven Metering Pump
2. Original Pump GPH rating is derated 20% due to Polymer viscosity. The
actual deration may vary depending on the polymer used
3. Control Modes Available *
a. Standard – 200 spm: 0-50 cp
b. HV1 (slightly reduced discharge speed) – 160 spm: 50-200 cp
c. HV2 (moderately reduced discharge speed) – 120 spm: 200-500 cp
d. HV3 (maximum reduced discharge speed)– 80 spm: 500-1000 cp
4. Connections: ½” x 3/8” or DN10 Depending on Model Selected
5. Power Requirements: 115VAC, 60 Hz, Single Phase
* Viscosity values are approximate and can vary widely per specific application. Use these
values as a guideline only and consult the factory for specific application capabilities