13
RANGE RESOLUTION ACCURACY
400mV 0.1mV
±(1.0% reading + 4 digits)4V 1mV
40V 10mV
400V 100mV
±(1.5% reading + 4 digits)
600V 1V
DC VOLTAGE
Input Impedance: 10MΩ
Overload Protection: 600VDC RMS for 400mV range. 600VDC RMS for all
other ranges.
RANGE RESOLUTION ACCURACY
-4°F to 1382°F 1°F 3% od rdg ± 9dgts
-20°C to 750°C 1°C 3% od rdg ± 9dgts
RANGE RESOLUTION ACCURACY
0°C to 50°C 0.1°C 3% od rdg ± 5dgts
RANGE RESOLUTION ACCURACY
33%RH to 99%RH 1%RH 3% of rdg ± 5dgts
TEMPERATURE HUMIDITY
INDOOR TEMPERATURE RANGE
INDOOR HUMIDITY RANGE
Input Impedence 10MΩ
Overload Protection: 250VDC or 250VAC RMS
Input Impedence 10MΩ
Overload Protection: 250VDC or 250VAC RMS