DC CURRENT
RANGE RESOLUTION ACCURACY
400µA 0.1µA ±(1.0% reading + 2 digits)
4000µA 1µA ± (1.0% reading + 2 digits)
400mA 100µA ± (1.2% reading + 2 digits)
10A 10mA ± (2.0% reading + 5 digits)
Overload Protection: 500mA/660V and 10A/600V fuse.
Maximum Inputs: 400mA DC RMS on µA/mA ranges, 10A DC RMS on 10A
range. Autoranging for µA and mA ranges.
AC VOLTAGE
RANGE RESOLUTION ACCURACY
400mV 0.1mV ±(1.5% reading + 15 digits)
4V 1mV
±(1.0% reading + 4 digits)
40V 10mV
400V 100mV ±(1.5% reading + 4 digits)
600V 1V ±(2.0% reading + 4 digits)
Input Impedance: 10MΩ
Max. Input Voltage: 600VAC RMS
Frequency Range: 50~400Hz