4.0 TRAINING
4.1 It is the responsibility of the user and purchaser of this equipment to ensure that they are familiar with these
instructions, trained in the correct care and use of, and are aware of the operating characteristics, application limits,
and the consequences of improper use of this equipment.
IMPORTANT: Training must be conducted without exposing the trainee to a fall hazard. Training should be repeated on a
periodic basis.
5.0 INSPECTION
IMPORTANT: If this equipment has been subjected to forces resulting from the arrest of a fall, it must be immediately
removed from service and destroyed.
5.1 FREQUENCY: Before use, visually inspect the anchor per the following steps:
STEP 1:Inspect the D-ring, plate, and bolts for physical damage. Look carefully for any signs of cracks, dents, or
deformities in the D-ring. Ensure that nuts are tightened to proper torque per manufacturers instructions.
STEP 2:Inspect the D-ring, plate, and bolts for signs of corrosion.
STEP 3:Ensure that the condition of the structure will support the anchor loads (see Anchorage Strength
Requirements). An anchor connected to questionable material or surfaces should not be used.
STEP 4:Ensure that the anchor is securely attached at all times.
STEP 5:Inspect each system component or subsystem per written instructions from manufacturer (inspection
procedures for other elements of the Compliance in a Can kit are included in this manual).
STEP 6:Record the inspection date and results in the inspection log included in the back of this manual.
NOTE: If inspection reveals a defective condition, remove the unit from service immediately and destroy, or contact
PROTECTA for more information. Only PROTECTA is authorized to make repairs to this equipment.
6.0 CLEANING, MAINTENANCE, AND STORAGE
6.1 No scheduled maintenance is required. If you have any questions concerning the condition of your AJ720A
Concrete Anchor, or have any doubts about putting it into service, contact PROTECTA. Additional maintenance and
servicing procedures (i.e. replacement parts) must be completed by PROTECTA. Unused components must be
stored in a clean dry location.
7.0 SPECIFICATIONS
7.1 ANCHOR PLATE AND D-RING
MATERIAL: Zinc plated stamped steel D-ring. Painted steel plate.
MINIMUM BREAKING STRENGTH: 5,400 lbs. minimum
WEIGHT: 3 lbs. (including anchor bolts)
SIZE: 6 in. X 6 in. X 1/4 in. steel plate, 9/16 in. diameter holes, 4 in. X 1/2 in. diameter anchor bolts.
CAPACITY: 310 lbs. total (one person, clothing, equipment).
7.2 ANCHOR BOLTS
LENGTH: 3.75 IN.
DIAMETER: .50 IN
SPECIFICATIONS: Meets GSA Specification FF-S-325, Group II, Type 4, Class 1.
ASTM E488.