Do you have a question about the PSS M Series and is the answer not in the manual?
Key safety precautions including handling voltage, batteries, and proper grounding.
Explains warning and caution symbols to ensure user comprehension and safety.
Overview of the UPS series, highlighting capacities, modularity, and N+X redundancy.
Details on 1-Phase I/O, DSP control, configurable batteries, intelligent charging, and LCD display.
Procedures for checking the UPS upon arrival and verifying its contents.
Visual identification of front and rear panel components of the UPS module.
Introduction to the LCD display and control buttons for UPS operation and settings.
Guidelines for optimal placement, temperature, humidity, and altitude for UPS installation.
Requirements for installing external circuit breakers for power input and battery protection.
Details on cable dimensions, selection, and electrical safety for power connections.
Step-by-step guide for connecting input and output power cables to the UPS.
Instructions for correctly connecting the battery strings to the UPS.
Overview of installing multiple UPS units for parallel operation.
Procedures for physically installing UPS modules into cabinets for parallel systems.
How to connect UPS modules using control cables for parallel operation.
Essential conditions for reliable operation of paralleled UPS modules.
Explanation of different UPS operating states: Normal, Battery, Bypass, ECO, and Parallel.
Procedures for safely turning the UPS unit on and off.
Step-by-step guide to start the UPS from a completely off state without utility power.
How to disable the inverter while maintaining bypass or utility power.
Safe procedures for shutting down the UPS and its connected load.
Comprehensive guide to interpreting information displayed on the UPS LCD screen.
Overview of setting various UPS operational parameters via the LCD interface.
Setting the UPS operation mode via the LCD interface.
Configuring the UPS output voltage through the LCD panel.
Adjusting the UPS output frequency using the LCD controls.
Setting the connected battery capacity for accurate UPS operation.
Configuring the number of batteries in the UPS system.
Setting the upper threshold for bypass input voltage.
Setting the lower threshold for bypass input voltage.
Enabling or disabling audible alarms from the UPS buzzer.
Configuring the UPS to perform automatic battery health checks.
Assigning a unique identification number to each UPS in a parallel setup.
Specifying the total number of UPS units in a parallel configuration.
Setting the redundancy quantity for enhanced reliability in parallel systems.