The wall sleeve must be installed before the air conditioner or heat pump chassis can be
set in place. Read the instructions thoroughly before proceeding.
Made in USA
Contents
KIT ACCESSORIES ..................................................................................................... 2
DRAIN KIT ....................................................................................................... 2
SUBBASE, LEVELING LEGS, MAIN DUCT, AND HYDRONIC HEAT KITS ........................ 2
PRE-INSTALLATION CONSIDERATIONS .................................................................. 3
OUTDOOR ENCLOSURE PANEL REMOVAL .............................................................. 3
WALL SLEEVE INSTALLATION.................................................................................. 4
PTAC
W
ALL
S
LEEVE
INSTALLATION INSTRUCTIONS
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during installation or repair it is possible to place yourself in a
position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to
instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of
specific good safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual, the
precautions listed here take precedence.
Part No. A3495105
Printed in USA
August 2005
When 230/208 volt units are to be installed, the power
supply may be either cord connected or permanent
wiring. Permanent wiring may be done through the hard
wire junction box, or the accessory subbase.
When 265 volt units are to be installed, the power supply
must be permanent wiring. Permanent wiring may be
done through the accessory hard wire junction box, or
the accessory subbase. An exposed cord connection
on 265 volt units is not permitted.
The subbase accessory includes leveling legs. If added
wall sleeve support is required and the subbase is not to
be used an accessory leveling leg kit may be installed.
Question and Answer IconNeed help?

Do you have a question about the PTAC WALL SLEEVE and is the answer not in the manual?

PTAC WALL SLEEVE Specifications

General IconGeneral
MaterialGalvanized Steel
Depth16 inches
Width42 inches
Installation TypeWall Mount
CompatibilityPTAC units
Dimensions42" x 16" x 16.25"

Summary

Attention Installing Personnel

Kit Accessories

Drain Kit

Accessory for indoor/outdoor drain. Install before wall sleeve.

Subbase, Leveling Legs, Main Duct, and Hydronic Heat Kits

Requires drilling. Mount kits on sleeve before wall installation if clearances are minimal.

Pre-Installation Considerations

Outdoor Enclosure Panel Removal

Steps to remove the sleeve stiffener and rear closure panel before installation.

Wall Sleeve Installation

Wall Sleeve Attachment to Opening

Procedure for mounting the wall sleeve securely into the wall opening using fasteners.