Remove contaminants around
the lube point.
Remove the grease nipple and install
appropriate adaptors.
To position the window properly, align the
on the housing cap with the on the body.
When the selected dispensing period of
the Pulsarlube E has completed, remove
the lubricator from the application.
Using a hand tool such as a flat-head
screwdriver, detach the PCB from the unit.
Remove the batteries.Firmly push the Mode Selector into the slot
of the desired period.
Unscrew the screws to remove the battery
cover.
Installation/Disposal Guidelines Product Details
Turn the housing cap counterclockwise
and unscrew the cap.
Remove the protector.
Housing
Cap
Battery Cover
Battery
Piston
PCB
Base
Lubricant
Reservoir
Protector
Mode
Selector
Connecting
Thread (1/4" PT)
1
6
Note the installation date and the scheduled date of
lube cycle completion on the label of the Pulsarlube E.
The Pulsarlube E is an eco-friendly product that can
be disposed of separately. Turn the housing cap
counterclockwise to disassemble the product for
proper disposal.
Pull out the red Mode Selector from the
default OFF position.
2
Dispose of remaining plastic components
complying with local regulations for recycling.
Warning
Do not cut, puncture, or reuse lubricator.
Note
3
4
5
9
7
8
12
10
11 14
13
If the product is installed at a 45°
or 90° angle, please use an angle
adapter with a diameter greater than
or equal to 1/4".
For remote installation using an 8mm
O.D. tubing, keep the maximum
distance at 1m (3ft) or less.
High backpressure can cause a delay
in dispensing (must be under 5 bar).
Mounting Installations
Ensure a clear passage using a manual
grease gun.
Note 1
Remove any hardened grease
by purging the lube point with a manual grease gun.
Note 2
The grease in the equipment and the grease
contained in the unit should be the same or compatible.
Note
Please note there is a delay before the actual dispensing
starts. It may take up to 1~3 weeks for enough gas to be formed
depending on the dispensing setting & installation condition.
Question and Answer IconNeed help?

Do you have a question about the Pulsarlube E series and is the answer not in the manual?

Pulsarlube E series Specifications

General IconGeneral
BrandPulsarlube
ModelE series
CategoryDispenser
LanguageEnglish

Summary

Installation and Mounting Procedures

Installation Steps

Follow steps for preparing lube point, setting mode, and disassembling unit for installation.

Mounting Backpressure and Angle

Ensure backpressure is under 5 bar; use angle adapter for 45° or 90° installations.

Remote Installation Tubing

For remote mounting, use 8mm O.D. tubing with a maximum distance of 1 meter.

Disposal of Components

Disassemble unit by turning housing cap counterclockwise for proper disposal.

Pulsarlube E Lubricant Specifications

Standard Lubricant Types

Details on PL1 through PL10 lubricants, including grease type and description.

Dispensing Volume Chart

Chart showing daily dispensing volumes for different periods and unit capacities.

Product Certifications

List of certifications including IECEx, ATEX, KCs, UL, and IP68 ratings.

Safety and Warranty Information

Safety Precautions

Warnings regarding intrinsic safety, electrostatic charging, battery handling, and flammable atmospheres.

Product Warranty and Shelf Life

Information on the 1-year shelf life and warranty period, excluding collateral damage.