Safety valve
The safety valve is set to the maximum allowable pressure of the pressure tank. lt is not permitted to adjust the safety valve or remove its
seal.
Cleaning of intake lter
► The copper l ter protects against penetration of foreign bodies and dust.
► lt is necessary to clean or replace this lter if the performance drops or no later thon after 100 operating hours.
► Minar dust deposits con be cleaned with a brush or an air gun.
► If there is a lot of dirt. soak the lter in petrol for three minutes and clean it carefully. Then blow it dry.
Pressure switch setting
The pressure switch is factory-set.
Switch-on pressure is approx. 6 bar. Switch-off pressure is 8 bar.
Safety valve
Warning : DO NOT REM OVE OR ATTEMPT TO ADJUST THE SAFETY VALVE!
This valve (6) should be checked under pressure occasionally by rotating the valve with hand. If air leaks after the valve has been released,
or valve is stuck, it MUST be replaced.
Thermal overload protector
CAUTION : THIS COMPRESSOR IS EOUIPPED WITH AN AUTOMATIC RES ET THERMAL OVERLOAD PROTECTOR. WHICH WILL
SHUT OFF THE MOTOR IF IT BECOMES OVERHEATED. IF THERMAL OVERLOAD PROTECTOR SHUTS MOTOR OFF
Si le protecteur contre la surcharge thermique arrête fréquemment le moteur, recherchez les causes suivantes.
►Low voltage.
►Clogged air filter.
►Lack of proper ventilation.
CAUTION : IF THE THERMAL OVERLOAD PROTECTOR IS ACTUATED, THE MOTOR MUST BE ALLOWED TO COOL DOWN BEFORE
START-UP IS POSSIBLE. THE MOTOR WILL AUTOMATICALLY RESTART WITHOUT WARNING IF LEFT PLUGGED INTO ELECTRICAL
OUTLET AND UNIT IS TURNED ON.