WINDOW INSTALLATION COLD AIR
Tools Needed
Knife
Duct tape
COLD AIR EXTENSION PIPE INSTALLATION INSTRUCTIONS
This accessory can be used in some environments, such as the cab, where it is not convenient to place the
Pundmann Arctix for cold air to reach the position we want. Remove the 2 rubber plugs on the front panel of
Pundmann Arctix and align the adapter with Pundmann Arctix. Tighten the two screws, hold the adapter with one hand, and pull the
air duct to the desired position.
WHEN ADJUSTING THE POSITION OF THE COLD AIR PIPE, PRESS THE EXTENSION ADAPTER WITH THE OTHER HAND
The picture above shows an example of how to assemble a
hot-air pipe using a component that you can get in our shop. If
you have any questions, please contact the manufacturer, he
will certainly answer all your questions concerning the
assembly of our product.
AIR FILTER CLEANING
CARE AND CLEANING
Always unplug the unit before cleaning or servicing.
DO NOT use ammable liquids or chemicals to clean the unit.
DO NOT wash the unit under running water. Doing so causes electrical danger.
DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced
with a new cord from the manufacturer.
Always clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.
Drain the unit’s water collection tray by tilting the machine backwards.
After draining the water run the unit on FAN mode for 12 hours in a warm room to dry it and prevent mold.
Turn off the unit and unplug it.
Clean the air lter . Always reinstall the clean, dry lter before storing.
AIR FILTER CLEANING MALFUNCTION DIAGNOSIS
SYMPTOM POSSIBLE CAUSE SOLUTION
E0 Error Code.
Communication failure between driver
board and control board.
Contact the consumer service.
E1 Error Code Temperature sensor error. Contact the consumer service.
Unit does not cool well
The air conditioner doesn’t work at
COOL or STRONG mode.
Contact the consumer service.
The air lter is blocked with dust or
animal hair.
Turn off the unit and clean the lter according
to instructions.
Exhaust hose is not connected or is
blocked
Turn off the unit, disconnect the hose, check
for blockage and reconnect the hose.
The unit is low on refrigerant. Contact the consumer service.
The windows and doors in the room
are open.
Make sure all windows and doors are closed.
The room area is too large. Double-check the cooling area.
There are heat sources inside the room. Remove the heat sources if possible.
The oor is not level. Place the unit on a at, level surface.
The unit is noisy and vibrates
too much
The air lter is blocked with dust or
animal hair.
Turn off the unit and clean the lter according
to instructions.
The unit makes a gurgling
sound
This sound is caused by the ow of
refrigerant inside the unit.
This is normal.
Unit stops frequently
The exhaust hose is blocked, extended
or otherwise restricted.
Remove the exhaust hose to see if the unit
continues to operate. If yes, shorten the
extension, reduce the number of bends or
eliminate restriction