WARRANTY
DR Distribution guarantees that any part*, which we find to be defective in
materials or workmanship will be repaired or replaced free of charge for the
parts and any service labour for a period of 24 months for residential use and 12
months for commercial use from the date of purchase,
as the original purchaser
of a Pureheat product, provided that all service be pre authorised by DR
Distribution.
*The heater warranty does not cover service calls related to over- temperature
safety devices activating and shutting the heater down.
*This Warranty does not cover failure due to accidental damage, misuse or
negligence, nor does it cover any consequential damages.
Important: If you are experiencing difficulties with the operation
or believe that your Pureheat heater is faulty in any way,
contact D R Distribution on
02 9618 3842
For the purpose of this warranty, it is a condition that the “wired in” models must
be installed by a registered electrical contractor and must be wired in
accordance with our wiring instructions. Similarly, this warranty becomes void if
the heater is serviced, repaired or altered by anyone other than D.R. Distribution
or its authorised Service Agents or if parts, other than approved parts, have been
used.
Record the date of purchase below and retain this card, together with your
purchase invoice for your own future reference.
The benefits conferred by this warranty are in addition to all other rights and
remedies which the consumer has under the Trade Practices Act and other
legislation.
OE Series 2.4kW, 3.5Kw, 4.5kw
INSTALLATION INSTRUCTIONS
IMPORTANT:
All Odyssey-Eco heaters are designed for wall mounting only and must not be used
for any portable application.
Wiring must be carried out by an authorised electrician in accordance with all
relevant Australian and local wiring standards.
Before obtaining access to terminals, all supply circuits must be disconnected.
OE24 MODELS c/w Flex & Plug:
1. Refer Odyssey Template & Installation Instructions enclosed separately with the heater.
2. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
3. The heater must not be located in front of a socket-outlet
OE35 and OE45 MODELS Hardwired:
1. Remove both plastic side vents by unscrewing the two recessed screws on each side.
2. Remove front panel by undoing the 2 screws on either side of the heater.
3. Bring all electrical supply wiring through the cable entry at the top left hand side of
the rear face.
4. The heater should be mounted a minimum of 50mm (2”) above the top of the floor or
floor covering.
Notes:
The heater must not be recessed and should have a clearance on either side
and above the heater of at least 200mm to allow for unobstructed airflow.
When selecting a position for the heater care must be taken not to position
the heater close to curtains and other combustible materials.
The heater must not be located immediately below a socket-outlet.
5. For the quietest operation, firmly screw the unit onto the wall at all four mounting pad
points located in the corners at the back of the heater.
6. Care must be taken when mounting heater on the wall that no twisting of the unit
occurs. It may be necessary to pack the rear panel with washers to overcome this.
7. The heater must be connected to a fixed, single phase 240 volts a.c. supply, through
an isolating switch and in accordance with the relevant local regulations.
Notes:
All connections must be tight.
Do not use this heater with an external programmer, timer or any other
device that switches the heater on automatically, since a fire risk exists if the
heater is covered or positioned incorrectly.
The heater must not be located in front of a socket-outlet
8. Replace front cover and tighten screws.
9. Fit the two side panels supplied loose with the heater. (Do not over tighten and distort
front panel).
10. Test heater, ensuring all facets of the unit’s operation are fully functional.
NAME:
ADDRESS:
PURCHASED FROM:
DATE OF PURCHASE:
MODEL NO:
SERIAL
NO:
INSTALLED BY: DATE:
PUREHEAT
D R Distribution Pty Ltd
Unit 9 No 3 Lancaster St Ingleburn NSW 2565
Ph 02 9618 3842
www.drdistribution.com.au
Question and Answer IconNeed help?

Do you have a question about the pureHeat ODYSSEY eco OE Series and is the answer not in the manual?

pureHeat ODYSSEY eco OE Series Specifications

General IconGeneral
BrandpureHeat
ModelODYSSEY eco OE Series
CategoryHeater
LanguageEnglish

Summary

Pureheat Heater Warranty Information

Warranty Coverage and Conditions

Covers defects for 24/12 months, excludes misuse/damage, requires authorized installation/service.

Pureheat Heater Installation Instructions

General Installation and Safety

Wall mounting, authorized electrician wiring, circuit disconnection, clearance, and placement guidelines.

Model-Specific Installation

Details for OE24/OE35/OE45 models, including panel removal, wiring, and mounting height.

Final Connection and Operation Checks

Secure mounting, 240V supply via isolating switch, tight connections, testing, and timer use advisory.

Pureheat Heater Operating Instructions

Fan-Assisted Heating and Thermostat

Heater controls fan and elements via thermostat based on room temperature.

Thermostat Adjustment for Comfort

Guide on setting the thermostat for optimal room temperature control.

24hr Timer Operation

Instructions for setting timed periods for heater operation using the timer tabs.

Important Notes and Safety Precautions

User Safety and Supervision

Guidance on safe appliance use, child supervision, and avoiding obstructions.

Operational Safety Warnings

Warnings against overheating, covering, and suitability for bathrooms; cut-out reset procedure.

Pureheat Heater Cleaning Guide

Cleaning Procedures

Instructions for cleaning external surfaces, air outlets, and mesh grills.