3. Push the tubing firmly into the side of the spray nozzle tee (Figure 5). Pull gently to
confirm you have secure connections then push back in. If leakage occurs, remove
tubing by pushing on the green circle, pushing the tubing in, pulling the tubing out and
then releasing the green circle. Trim ¼ inch o the tubing before reinserting.
4. Using the plastic fasteners (Figure 5), or zip ties, install the tubing and spray nozzles
above the center of each stall and six (6) feet inside each exterior door. Do not install
above fifteen (15) feet from the floor. Use cable wire if necessary. Make sweeping turns
with the tubing around corners to avoid kinking.
5. After all the spray nozzles have been installed, run the beginning of the tubing from the
discharge elbow on the brass cross assembly (Figure 3). Tighten with a wrench. Leave
four (4) feet of slack in the line to allow for easy shifting of the lid to add insecticide or
to remove the lid for drum cleaning.
6. At the end of the tubing attach
a bleed valve to shut o the line
and hold pressure (Figure 6). It is
recommended to end the tubing at
the drum for bleeding liquid and air
from the line into the drum.
FIGURE 5
FIGURE 6
System_Manual_2020.indd 9System_Manual_2020.indd 9 12/23/20 10:18 AM12/23/20 10:18 AM