OUTPUT A & B Wiring:
Learning Inputs:
Signal Strength Indicator:
Learning Keyfobs:
FAULT OUTPUT Wiring:
ARM / DISARM:
UR2-WE 
 Dual channel universal receiver   
 for Enforcer inputs and keyfobs
( 0845 6434 999 (UK). +44(0)1709 535 225  * customer.support@pyronix.com     www.pyronix.com    Pyronix Limited,Pyronix House,Braithwell Way, Hellaby, Rotherham, S66 8QY, UK                RINS1702-4
Environmental Class II
ENGLISH
15s
≤300s
≤300s
>5s
>5s
0-9
0-9
A-F
≤300s
FAULT
FAULT
Technical Information Summary:
(SLOW)
(LENTO)
(FAST)
(VELOCE)
Product Information
Warranty
START
Each output allows a maximum of 10x Wireless Inputs and 6x Wireless 
Keyfobs to be learnt. The relays will wire directly to an input on the 
control panel (normally open or normally closed).The outputs should be 
connected to an input programmed according to the device learnt (e.g. 
Keyswitch input for keyfobs, or Intruder input for wireless devices)
 Fault Output: 
This output will activate if there are any of the following faults:
Low Battery  /  Jamming  /  Supervision   /  Tamper
The output should be connected to an input programmed as ‘Fault’.
 Arm / Disarm Status: 
In order to receive alarm events from learned devices, the 'ARM' terminal 
should be connected to an output that monitors the ARM/DISARM status of 
the control panel. The shown dip switch is used to select 0v or 12v applied 
when the control panel is armed. 
PIR’s will only trigger a channel relay if the UR2 is in an Armed State.
 Learning Inputs: 
It is recommended that all inputs are learnt to one output (e.g. OUTPUT A) 
and all keyfobs are learnt to the other output (e.g. OUTPUT B) -A dot next 
to the letter/number indicates that an Input is connected to OUTPUT B.
  Learning Keyfobs: 
If learning keyfobs, the control panel input should be programmed as a 
keyswitch.
  Signal Strength Indicator:            
Shows the following for each input learned:
‘
A’:Excellent. ‘B’:Good. ‘C’:Bad. ‘     ’:Waiting for response/out of range
 Event Log /History: (Events display in realtime AND in Event logs)
 Clearing the Event Log       Deleting Inputs           Deleting Keyfobs 
 Pulse Outputs: 
Keyfob: Pressing      ,     or  
I  on the keyfob will activate the relay for the 
pulse time (3 or 60 seconds).
Input: The output will activate for the pulse time (3 or 60 seconds) after 
an input has activated. The pulse time will only be reset once all inputs 
are in a closed state.
Pressing  
II will display the UR2 status
 RED LED = ARMED, GREEN LED = DISARMED, ORANGE LED = FAULT
 Toggle Outputs: 
Keyfob: 
Pressing only the      button on the keyfob will activate the relay. 
Pressing only the      button will deactivate the relay.
Pressing 
 I will display the error LED (blinks orange 4 times).
Input: The output will activate after an input has activated. The output 
will only be reset, when either the same input is activated again, or a 
different input is activated.
Pressing  
II will display the UR2 status (same as pulse mode).
 Walk Test Mode: 
The channel relay will open for 3 seconds and then the relay will close 
again after a successful walk test.
Output A and Output B:
OUTPUT
  (A/B) 
OUTPUT
  (A/B) 
OUTPUT
  (A/B) 
OUTPUT
  (A/B) 
FAULT
FAULT
Control 
Panel
UR2-WE
+12VDC
Supply
POWER SUPPLY
10
DISPLAYS EVENTS IN ORDER ONCE DISARMED
MOSTRA GLI EVENTI ORDINE UNA VOLTA DISARMATO
Supply Voltage:                     9V – 15V
Current Consumption: 80mA (min) – 400mA(max, all outputs active)
Output A:                              3A @ 30VDC
Output B:                              3A @ 30VDC  
Fault:                                    3A @ 30VDC
Arm / Disarm status:     0V (0V ARM), 9-15V (12V ARM)
Radio Frequency:                  868MHz, FM Transceiver Narrow Band
Dimensions Plastic Box: 173x125x32mm 
Dimensions PCB: 135x90x15mm
Operational Temperature: -10°C to +50°C
Storage Temperature:   -40°C to +80°C          
Humidity: 85% @ 25°
For electrical products sold within the European Community. At the end of the electrical products 
life, it should not be disposed of with household waste. Please recycle where facilities exist. Check 
with your Local Authority or retailer for recycling advice in your country.
To prevent possible damage to components, any static charge on your body needs to be eliminated 
before touching the inside of the unit. This can be accomplished by touching some rounded/earthed 
metallic conductor such as a radiator/pipework immediately before handling the product.
This product is sold subject to our standard warranty conditions 
and is warranted against defects in workmanship for a period of 
two years. In the interest of continuing care and design, Pyronix 
Ltd reserves the right to amend specifications, without giving 
prior notice.Please see the control panels programming manuals 
for further information.
M
N/C (Normally Closed)N/O (Normally Open) N/O  DEOL N/C  DEOL
N/C (Normally Closed)N/O (Normally Open) N/O  DEOL N/C  DEOL
= ALARM
= TAMPER
= ALARM
= TAMPER
Example Disarm Status 
after Alarm (Output A)
0V 
12V
0V 
12V
12V
ARM
0V
ARM