ttrroouubblleesshhoooottiinngg
TThhee iiggnniittiioonn ccoommeess oonn,, bbuutt tthhee ssttaarrtteerr wwiillll nnoott ccrraannkk..
Does it start with the key in the ignition? If so, does the vehicle have a VATS Pass-Key system?
Will it start with the brake pedal depressed? (Make sure to disconnect the brake shutdown when performing this
test.) If so, it may have a brake/starter interlock.
Is the correct starter wire being energized? Check by energizing it yourself with a fused test lead.
TThhee ssttaarrtteerr ccrraannkkss ffoorr ssiixx sseeccoonnddss bbuutt d
dooeess nnoott ssttaarrtt..
Either the wrong ignition wire is being energized, the unit's ignition and accessory wires have been connected
backwards, or the vehicle has two ignition circuits. Try activating the unit with the ignition key in the “run”
position. If the vehicle then runs normally, retest your ignition system.
TThhee ssttaarrtteerr ccoonnttiinnuueess ttoo ccrraannkk eevveenn tthhoouugghh tthhee eennggiinnee hhaass ssttaarrtteedd..
Has the tach wire been learned? See
Tach Learning
section of this guide.
Is the tach wire receiving the correct information? Either the wrong tach wire has been used, or a bad connec-
tion exists.
TThhee cclliimmaattee ccoonnttrrooll ssyysstteemm ddooeess nnoott wwoorrkk wwhhiillee tthhee uunniitt iiss ooppeerraattiinngg tthhee vveehhiiccllee..
Either the wrong accessory wire is being energized or more than one ignition or accessory wire must be ener-
gized in order to operate the climate control system.
TThhee rreemmoottee
ssttaarrtt wwiillll nnoott aaccttiivvaattee..
1. Check harnesses and connections. Make sure the harnesses are fully plugged into the remote start module.
Make sure there are good connections to the vehicle wiring.
2. Check voltage and fuses. Use a meter and check for voltage between the red wire in the 5 pin ribbon harness
and the black ground wire. If you have less than battery voltage, check both 30A fuses on the relay satel-
lite. Also make sure that the ground wire is going to a chassis ground and not to something under the dash.
3. Check diagnostics. The diagnostics will tell you which shutdown is active or not connected.
TThhee rreemmoottee ssttaarrtt wwiillll aaccttiivvaattee bbuutt tthhee ssttaarrtteerr nneevveerr eennggaaggeess..
1. Check for voltage on the purple starter wire two seconds after the remote start becomes active. If there is
voltage present, skip to Step 4. If there is not voltage present, advance to Step 2.
2. Check the 30A fuses.
3. Check diagnostics. If the gray/black wire is detecting ground upon activation, the starter will not crank.
4. Make sure the purple starter wire is connected on the starter side of the optional starter kill relay.
5. Does the vehicle have an immobilizer? Some immobilizer systems will not allow the vehicle to crank if active.