Questions and Answers

  • C
    Carolyn WrightAug 18, 2025
    Why won't the pilot light on my Qlima Patio Heater light?
    • M
      marshallandreaAug 18, 2025
      If the pilot light on your Qlima Patio Heater won't light, several factors could be at play. First, ensure the gas valve is turned ON. If it is, check the tank fuel level and refill if empty. A blocked pilot injector could also be the culprit, requiring cleaning or replacement. Additionally, there might be air in the supply system; purge it by pressing the control knob until you smell gas. Inspect all fittings for loose connections and tighten them. Finally, low gas pressure could be the issue, necessitating a cylinder replacement.
  • C
    Cindy KennedyAug 20, 2025
    What to do if the burner will not light on Qlima Patio Heater?
    • R
      Ricky BrewerAug 20, 2025
      If the burner of your Qlima Patio Heater won't light, it could be due to several reasons. A low gas pressure, possibly because the tank is near empty, requires you to refill the gas tank. Check for any blockages and remove them. Ensure that the control valve is turned ON. A bad thermocouple might also be the cause, needing replacement. Make sure the pilot light assembly is properly placed. Correct the position of the heater and try again.
  • Y
    ybuckleyAug 23, 2025
    Why does the pilot light keep going out on my Qlima Patio Heater?
    • K
      Kimberly ButlerAug 23, 2025
      If the pilot light on your Qlima Patio Heater won't stay on, it might be due to a lack of fuel pressure. Try keeping the variable knob depressed for 10-20 seconds or more after the pilot light ignites. Also, check if the tank is near empty and refill it. Clean any debris around the pilot. Tighten any loose connections. If these steps don't work, the thermocouple might be bad and require replacement. Finally, check for gas leaks in the line and tighten connections if necessary.
  • J
    Jaclyn SmithAug 26, 2025
    How to fix a low burner flame on a Qlima PGU 2013 Patio Heater?
    • H
      Herbert PattonAug 26, 2025
      A low burner flame on your Qlima Patio Heater may be caused by a bent or twisted supply hose. Straighten the hose and perform a leak test. Alternatively, there might be a blockage in the burner injector, which you should clean or replace.
  • D
    derekroweAug 28, 2025
    Why is the emitter glowing unevenly on my Qlima Patio Heater?
    • M
      Michael ValdezAug 28, 2025
      If the emitter on your Qlima Patio Heater glows unevenly, it could be due to a blockage in the burner injector. Try cleaning or replacing the burner injector. Another cause might be that the base is not on a level surface, so place the heater on a level surface. Low gas pressure can also cause this issue, so replace the cylinder with a new one.
  • E
    Edwin SullivanAug 30, 2025
    What to do if burner flame goes off immediately after ignition on Qlima PGU 2013 Patio Heater?
    • P
      Paul MirandaAug 30, 2025
      If the burner flame on your Qlima Patio Heater goes off immediately after ignition, it is likely due to low gas pressure. To resolve this, let the pilot flame stay lit for 10 minutes before setting the variable knob to LO.
  • E
    Elizabeth RiveraSep 1, 2025
    Why is my Qlima PGU 2013 producing thick black smoke?
    • E
      ellislisaSep 2, 2025
      If your Qlima Patio Heater is producing thick black smoke, it indicates a blockage in the burner. Turn off the heater and let it cool down. Then, remove the blockage and clear the burner both inside and outside.
  • E
    Elizabeth JeffersonSep 4, 2025
    What causes carbon buildup on a Qlima PGU 2013 Patio Heater?
    • S
      shawcassieSep 4, 2025
      Carbon buildup on your Qlima Patio Heater is usually due to dirt or film on the reflector and flame screen. Clean the reflector and flame screen to resolve this issue.
  • J
    James TorresSep 6, 2025
    What to do if the pilot light won't stay on for my Qlima Patio Heater?
    • K
      Karen DavilaSep 7, 2025
      If the pilot light on your Qlima Patio Heater won't stay lit, consider these possibilities: * Lack of fuel pressure: Keep the variable knob depressed for at least 10-20 seconds after the pilot light ignites. * The tank may be nearly empty: Refill the gas tank. * There might be debris around the pilot: Clean the area. * Loose connections could be the problem: Tighten them. * A bad thermocouple: Replace it. * A gas leak in the line: Check the connections.
  • F
    fullerjudySep 9, 2025
    Why the burner will not light on my Qlima PGU 2013 Patio Heater?
    • J
      Jodi RileySep 9, 2025
      If the burner on your Qlima Patio Heater isn't lighting, check the following: * Low pressure: The tank may be nearly empty, so refill it. * Blocked opening: Remove and clean any blockages. * Control not ON: Turn the valve to the ON position. * Bad thermocouple: Replace the thermocouple. * Bent pilot light assembly: Place the pilot properly. * Incorrect location: Position the heater properly and try again.

Qlima PGU 2013 Specifications

General IconGeneral
Heat input (kW)13
Consumption (g/h)945
IgnitionPiezo
MaterialSteel
Type of gasPropane
SafetyTip-over switch