Table: Sensor Event Severity Table
Sensor Name Sensor
Number
Sensor Type Event /Reading Type Event Triggers Event Severity
MB Temp
FP Temp
DIMM Temp
BP Temp
CPU0 Temp
CPU1 Temp
IOH Temp
40h
41h
42h
43h
44h
45h
46h
Temperature – 01h Threshold – 01h Upper Non-Critical - going high EVENT_SEVERITY_NON_CRITICAL
Upper Critical - going high EVENT_SEVERITY_CRITICAL
PROC_HOT0
PROC_HOT1
IOH_THERMALTRIP
21h
22h
25h
Temperature – 01h Digital Discrete – 03h State Asserted
EVENT_SEVERITY_CRITICAL
P1V5_ICH
P5V
P1V8_AUX
P12V
P3V3
P3V3_STBY
31h
32h
33h
34h
35h
36h
Voltage – 02h Threshold – 01h Lower Non-Critical - going low
Lower Critical - going low
Upper Non-Critical - going high
Upper Critical - going high
EVENT_SEVERITY_NON_CRITICAL
EVENT_SEVERITY_CRITICAL
EVENT_SEVERITY_NON_CRITICAL
EVENT_SEVERITY_CRITICAL