[3] Log ECC error
Byte Field Value Description
1 NetFunLun 10h
2 Platform Event Command 02h
3 Generator ID 01h
4 EvM Rev 04h
5 Sensor Type 0Ch
6 Sensor Number 60h-71h Memory Sensor Number
7 Event Dir | Event Type 6Fh
8 EventData1 Axh
00h:Correctable ECC error
01h:Uncorrectable ECC error
08h:Spare
9 EventData2 FFh
10 EventData3 XXh Error DIMM #
[4] Log PCI Error
Byte Field Value Description
1 NetFunLun 10h
2 Platform Event Command 02h
3 Generator ID 01h
4 EvM Rev 04h
5 Sensor Type 13h Critical Interrupt
6 Sensor Number 81h PCI SensorID
7 Event Dir | Event Type 6Fh
8 EventData1 Axh
04h:PCI PERR
05h:PCI SERR
07h:Bus Correctable Error
08h:Bus Uncorrectable Error
0Ah:Bus Fatal Error
9 EventData2 XXh PERR/SERR dev/fun num
10 EventData3 XXh PERR/SERR bus num
[5] Log IOH Error
Byte Field Value Description
1 NetFunLun 10h
2 Platform Event Command 02h
3 Generator ID 01h
4 EvM Rev 04h
5 Sensor Type 13h Critical Interrupt
6 Sensor Number XXh
82h:QPI SensorID
83h:INT SensorID
7 Event Dir | Event Type 6Fh
8 EventData1 Axh
07h:Core
08h:Non-Fatal
0Ah:Fatal
9 EventData2 XXh Local Error Bit (0 ~ 31)
10 EventData3 XXh
00d:QPI[0] Error
01d:QPI[1] Error
02d:QPI[0] Protocol Error
03d:QPI[1] Protocol Error
23d:Miscellaneous Error
24d:IOH Core Error
65