To charge the batteries using the off-board charger:
1. Position your power chair next to a standard electrical
outlet.
2. Be certain the controller power is turned off and the power
chair is in drive mode.
3. Plug the off-board charger into the off-board charger/
programming socket on the controller. See figure 18.
4. Plug the off-board charger into the electrical outlet.
WARNING! The LED lights on the charger indicate
different charger conditions at various times:
charger power on, charging in progress, and
charging complete. If the LED does not indicate that
charging is complete within 24 hours, unplug the
charger from the outlet and contact your Quantum
Rehab Provider. Refer to the manual supplied with
the charger for a complete explanation of these
Figure 18. Battery Charger
indicators.
5. When the batteries are fully charged, unplug the off-board charger from the electrical outlet and
then from the controller.
Battery Break-in
To break in new batteries for maximum efficiency:
1. Fully recharge any new battery prior to its initial use. This brings the battery up to about 90% of its
peak performance level.
2. Operate your power chair throughout the house and yard. Move slowly at first, and do not travel too
far until you become accustomed to the controls and break in the batteries.
3. Give the batteries another full charge of at least 8 to 14 hours and operate your power chair again.
The batteries will now perform at over 90% of their potential.
4. After four or five charging cycles, the batteries will top off at 100% charge and last for an extended
period.
Frequently Asked Questions (FAQs)
How does the charger work?
The battery charger takes the standard electrical outlet voltage (alternating current) and converts it to
24 VDC (direct current). The power chair batteries use direct current to run your power chair. When the
battery voltage is low, the charger works harder to charge the battery. As the battery voltage approaches
full charge, the charger does not work as hard to complete the charging cycle. When the battery is fully
charged, the amperage from the charger is nearly at zero. This is how the charger maintains a charge
but does not overcharge the battery.
Can I use a different battery charger?
You should use the charger supplied with the power chair. It is the safest, most efficient tool to charge
the batteries. We do not recommend using other types of chargers (e.g., an automotive battery charger).
NOTE: Your power chair’s charger will not operate after the batteries have been discharged to
nearly zero voltage. If this happens, call your Quantum Rehab Provider for assistance.