----------------------------------------------------------------Engineers Of Clean Air----------------------------------------------------------------
30 Hymus Blvd., Pointe-Claire, Quebec, Canada H9R 1C9 Tel.:(514)630-4444 Fax:(514)630-4454 www.quatroair.com info@quatroair.com
Operations & Maintenance Manual
AF Air Purifier iSeries
AF1000RNP and AF2000RNP
1.0 INTRODUCTION
Congratulations! You are now the owner of a QUATRO AirFlow Series RNP system, an advanced effective air purifier, designed specifically to help protect the
human respiratory system. You can expect a noticeable improvement in air quality as the unit begins the process of reducing microscopic airborne particulate.
The RNP system was designed to provide flexibility in the field. It can be used with adjustable discharge grills for simple recirculation or it can be converted to a
negative pressure system by replacing the adjustable grill with 6ā€(AF1000RNP) or 10ā€ (AF2000RNP) discharge collar which has been supplied.
This will allow the end user to exhaust clean air from the room to create a negative pressure environment.
2.0 PRECAUTION
Read all the instructions contained within this manual before operating this unit. Keep this manual, as it contains information for proper operation and
maintenance. Keep all fastening hardware tight to ensure that the unit is in good working condition. Familiarise yourself with the way in which filters
are removed, installed, and serviced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do
not use any two-wire electrical prong adapters to defeat the three-pronged plug on the end of the cord. When servicing the motor, be careful when
touching the exterior of the motor as soon as it has been turned off; it may be hot enough to be painful or cause injury. They are built to operate at
higher temperatures. Do not substitute any other filters (particulate or chemical) for those supplied, as this will alter the unit efficiency. DO
NOT SERVICE MOTOR OR CONTROL PANEL UNLESS UNIT IS UNPLUGGED FROM RECEPTACLE (ITS POWER SUPPLY)!
3.0 PRINCIPLE OF OPERATION
The air is drawn in through an intake grille located at the bottom of unit. The air then passes through the particulate, HEPA and optional odor filters.
The clean air is then released through the top discharge grills into the controlled space. The AF iSeries Purifier features a threefold method of
operation; a) captures general particulate; b) HEPA filter removes microscopic particulate matter; c) Optional Chemical filters adsorbs, reacts or
scrubs toxic or nuisance gases (optional).

Questions and Answers

  • R
    Robert MaddoxJul 29, 2025
    What to do if my Quatro Air Cleaner unit will not start?
    • J
      john24Jul 30, 2025
      If your Quatro Air Cleaner won't start, there are a few potential reasons. First, check the breaker box. It could also be due to a blown fuse, in which case you should replace the fuse. Finally, ensure the unit is properly plugged into the receptacle.
  • M
    Michael WilsonAug 6, 2025
    Why is there insufficient airflow in my Quatro Air Cleaner?
    • M
      Mr. Adam GibbsAug 6, 2025
      Insufficient airflow in your Quatro Air Cleaner can be caused by a couple of things. There might be an obstruction in the system, so try removing any obstructions. Alternatively, the filters could be clogged, so consider replacing them.
  • B
    Bryan MccallAug 13, 2025
    How to fix excessive noise from Quatro Air Cleaner?
    • A
      amandacollinsAug 13, 2025
      Excessive noise in your Quatro Air Cleaner may be due to the blower wheel contacting the cone, which requires you to realign or replace the wheel. It could also be caused by loose or off fan isolators, in which case you should replace the isolator.
  • H
    hollowayperryAug 21, 2025
    What to do if Quatro Air Cleaner has excessive airflow?
    • V
      vanessa19Aug 21, 2025
      If your Quatro Air Cleaner has excessive airflow, it's likely because the filters are not in place. Make sure to install the filters.

Summary

Introduction and Safety Precautions

2.0 PRECAUTION

Essential safety instructions to follow before operating the unit.

Initial Setup and Operation

7.0 START-UP

Step-by-step guide for powering on and starting the air purifier.

Filter Alerts and Maintenance Overview

8.1 FILTER-ALERT SYSTEM AND FILTER REPLACEMENT

How the filter alert system works and filter replacement procedures.

Detailed Filter Replacement Procedures

8.2 PARTICULATE FILTER REPLACEMENT

Detailed steps for replacing particulate and HEPA filters.

Blower Maintenance and General Inspection

8.6 RESETTING FILTER LIGHTS

Procedure to reset the filter service indicator lights.

Unit Usage, Troubleshooting, and Warranty

10.0 TROUBLESHOOTING GUIDE

Common issues, their causes, and suggested solutions.

System Conversion to Negative Pressure

UV Light Installation for AF1000

Quatro AF Series Specifications

General IconGeneral
BrandQuatro
ModelAF Series
CategoryAir Cleaner
LanguageEnglish