6) Full turn movement is set to 1.5s by default. If this time is too long (if after slates full cycle
the Shutter starts moving up or down), decrease this time with the parameter 72. If this time is
too short (if the slats will not turn for a full cycle), increase this time with the parameter 72.
Manual operation for Shutter with momentary switch
(par. 71 set to 0 and par. 1 set to 1)
Pressing the push-button for less than 0,5 second (short press), which is connected to I1 (up),
initiates up movement.
Pressing the push-button for less than 0,5 second (short press), which is connected to I2
(down), initiates down movement.
If the Shutter is moving, any press (of any push-button) will stop the movement.
Keeping the push-button, connected to I1 (up), pressed for more than 0,5 second (long press)
initiates up movement, until the push-button is released.
Keeping the push-button, connected to I2 (down), pressed for more than 0,5 second (long
press) , initiates down movement, until the push-button is released.
Manual operation for Shutter with toggle switch
(par. 71 set to 0 and par. 1 set to 0)
When toggle switch connected to I1 (up) is pressed initiates up movement, until the toggle
switch is released.
When toggle switch connected to I2 (down) is pressed initiates down movement, until the
toggle switch is released.
Manual operation for venetian blinds with momentary switch
(par. 71 set to 1 and par. 1 set to 1)
General rules:
- Short press (< 0,5 seconds) initiates shutter movement
- Long press (> 0,5 seconds) initiates slats movement