NOTE1: After the value of this parameter is changed, first exclude device (without setting
parameters to their default values), wait at least 30s and then re-include the device!
Parameter no. 72 – Slats tilting full turn time
Set the time, required by the slats, to make a full turn (180 degrees).
Values (size is 2-byte dec):
• default value 150 = 1.5 seconds
• 0 - tilting time disabled
• 1 - 32767 = 0.01seconds – 327.67 seconds
NOTE: If the set time is too long and a full turn was already performed, the device will start to
move up or down for the remaining time.
Parameter no. 73 – Slats position
This parameter is used to enable/disable the slats to return to the previously set position after
being activated via the Z-Wave gateway(hub), push-button operation or when the lower limit
switch is reached.