Parameter no. 90 Time delay for next motor movement
This parameter defines the minimum time duration between successive motor movements
(minimum time after which the motor is switched off and on again).
Values (size is 1-byte dec):
default value 5 = 500ms
1 - 255 = 0.1seconds 25,5seconds (100ms resolution)
Parameter no. 110 Temperature Sensor Offset Settings
Set value is added to or subtracted from the measured value to adjust the temperature report
sent by an external sensor (sold separately). This parameter only applies to the Celsius
temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 2-byte dec):
default value 32536
32536 - Offset is 0 °C.
1 - 100 - Where 1 stands for 0.1 °C and 100 stands for 10.0 °C added to the actual
measurement.
1001 - 1100 Where 1001 stands for -0.1 °C and 1100 stands for -10.0 °C subtracted from
the actual measurement.