Loading...
37
RETRACTABLE THRUSTER BTR185 - IT GB - REV004B
ELICA DI MANOVRA RETRATTILE - SISTEMA BASE
RETRACTABLE THRUSTERS - BASIC SYSTEM
* COMMON NEGATIVE FOR THE BATTERY GROUPS.
10 A
CN1
CN2
CAN1
CAN2
UP
DWN
CN3
POWER
DL3
DL2
DL1
LA STATUS
ERROR
C
-
COMC
-
SXC
-
DXI
-
SXI
-
DXLA
+
LA
-
LSC COM COMLS O
1
234567
M1
AA
SS
SX
+
-
DX
-
M2
POWER
DL3
DL2
DL1
LA STATUS
ERROR
LED GREEN
LED RED
1 POWER SUPPLY +
2 POWER SUPPLY -
3 TCD PLUGIN FEMALE PIN 1
4 TCD PLUGIN FEMALE PIN 2
5 TO RIGHT CONTACTOR
6 TO LEFT CONTACTOR
7 NEGATIVE GROUP REVERSING CONTACTOR
RTC R1 BOARD
RTC R1
ELECTRONIC
BOARD
BATTERY
12/24V
BATTERY ISOLATOR
BLACK
FUSE 4A
QUICK ACTING F
FUSE
see table on
page 4 or 20
SWITCH
RED
BLACK
RED
TO THE SERVICES
BATTERY
TCD 1042
TCD 1022
CONTROL CABLE
EXTENSIONS
(OPTIONALS)
*
MOTOR
TO THE
SERVICES
BATTERY
ACTUATOR
SWITCH
*
DETAIL RTC R1
BOARD
SPLITTER
(OPTIONAL)
LED BI-COLOR
EXTERNAL
LIMIT SWITCH
1 2
4
6
5
3
7
FUSE 10A
QUICK ACTING F

Other manuals for Quick BTR1808524