11
GB
RRC R902/12 - REV001A
MAINTENANCE - TECHNICAL DATA
MODELS R902 R904 R906 R908 R910 R912
INPUT CHARACTERISTICS
Power supply 10,5 ÷ 31 Vdc
Quiescent current 25 mA
Absorption with 2 relays activated 120 mA
OUTPUT CHARACTERISTICS
Relay number 24681012
Relay contact rating 15A
CHARACTERISTICS OF THE RECEIVER
Frequency 913.7 Mhz
Modulation FSK
Number of transmitters that
can be stored
50
EMC standard FCC TITLE 47 PART 15 SUBPART B CLASS B
GENERAL CHARACTERISTICS
Operating temperature from -15°C to +70°C
Dimensions (W x H x D) 143 x 141,7 x 61,4 mm
Weight (with all relays installed) 300 g 370 g
MAINTENANCE
The RRC radio receiver does not require particular maintenance. In order to ensure optimal operation of the re-
mote control, once a year verify cables and electrical connections.
TECHNICAL DATA
QUICK
®
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) this device must accept any interference received including interference that may cause undesired operation.
143 (5”
5
/8)
108 (4”
1
/4)
132 (5”
13
/64)
123 (4”
27
/32)
141,7 (5”
37
/64)
61,4 (2”
27
/64)
DIMENSIONS mm (inch) • R902 • R904 • R906 • R908 • R910 • R912