23
Quicksilver 905WE — System & Component Overview and Operaon
Disinfect the Fresh Water System
The following is a recommended procedure to disinfect the fresh water system:
1. Flush the enre system thoroughly by allowing potable water to ow through it.
2. Drain the system completely.
3. Fill the enre system with an approved disinfecng soluon. Check with your dealer for
recommended products, and follow the manufacturer’s instrucons.
4. Aer disinfecng, drain the enre system.
5. Flush the enre system thoroughly several more mes with potable water.
Maintenance
Maintenance of the fresh water system will require you to check the ngs and hoses to make sure
that there are no leaks. Before the winter season, the fresh water system must be completely drained
to avoid damage.
City Water Inlet
Included in the boat is a City Water Inlet which allows you to hook up to a fresh water source while at
a dock. The inlet contains a pressure regulator to control the ow of water to your boat. To connect,
simply aach the male quick disconnect ng (provided by Quicksilver®) to the City Water Inlet. Next
connect a water hose with a female quick disconnect ng end to the City Water Inlet. The inlet
bypasses the water tank so there is no need to turn on the water pump.
Boiler (oponal)
Your boat may come equipped with an oponal 22L boiler, located in the starboard ulity area in the
a berth. To operate, make sure the FRESH WATER switch is in the ON posion. Next, turn on the
WATER HEATER breaker located on the 230V main distribuon panel.
The boiler’s thermostat comes pre-set from the factory at 70
o
C. If you would like to adjust the water
temperature, refer to the boiler’s owners manual for explicit instrucons.
Maintenance
Maintenance of the boiler will require you to check the ngs and hose connecons regularly to
make sure that there are no leaks. The pressure relief valve must be acvated regularly to make sure it
is not blocked. This must be done when the water in the boiler is cool. The system should be ushed
several mes a year to prolong the life of the system.
Before the winter season, the boiler must be completely drained to avoid damage.
Boiler
22L boiler
Water inlet (from water pump)
Relief valve
Water outlet (to hot water lines)
Engine heat exchanger inlet / outlet