Section V - Operating instructions
Quincy Compressor 79
3. Check that condensate is discharged automatically from the condensate drain
outlet during operation.
NOTICE!
The dew point will deviate from nominal when the nominal conditions are exceeded.
If the dew point remains too high or unstable, consult section Problem solving.
Stopping
Procedure
1.Pressthestopbutton(2).
2.Closetheairoutletvalve.SeesectionIntroduction.
3.Switchoffthevoltage.
4.Openthemanualcondensatedrainvalve.
Taking out of operation
Procedure
1. Stop the compressor and close the air outlet valve.
2. Switch off the voltage and disconnect the compressor from the mains.
3.Depressurizethecompressor.Openthecondensatedrainvalve.
4.Shutoffanddepressurizethepartoftheairnetwhichconnectedtotheoutletvalve.
Disconnectthecompressorfromtheairnet.
5.Disconnectthecondensatepipingfromthelocalcondensatedrainsystem.