Installation
2 - 6 Verbatim Owner's Manual
K To set the date:
9 4 1 MM DD YY DW ENTER
MM is the month (01 for January, etc.), DD is the day of the month (07 for the
7th day of the month, YY is year (93 for 1993) and DW is the day of the week
(1 for Sunday, 2 for Monday, etc.) Entry of the DW is optional.
K To check the time:
9 4 2 ENTER
K To set the time:
9 4 2 HH MM SS ENTER
HH are the hours in 24 hour format (13 for 1 PM), MM for minutes (don’t
forget the leading zeros) and SS is the seconds. Entry of SS is optional.
K To clear the time and date back to a default time and re-initializes the real-
time clock chip:
935 7 ENTER
Note:
The preceding operation should only be necessary if the real-time clock chip
has been added or replaced in the field.
2.3.4 Printout at Regular Intervals
The Verbatim autodialer may be programmed to automatically log (print on the
printer) all input conditions at regular intervals, by entering the following code:
943 XXX.X ENTER
where XXX.X is the desired printing interval in hours, from 0.1 to 999.9
The first such printout will occur when the period elapses, rather than
immediately upon programming.
K To check the presently programmed printing interval enter the following
code:
943 ENTER
K To turn off the regular interval printing function enter the following code:
943 0 ENTER
K To immediately print a record of all current user programming enter the
following code:
944 ENTER