WIRING CONNECTIONS
If you are using a power supply, then decide which product will be
the Master Unit of the system and connect a 9-24Vdc power supply
as shown opposite. This connecon is connued through to every
device on the system to supply power. This will normally be the CSA
-FSU installed outside the washroom area. You can connect up to 10
devices to the CSA-FSU as shown in the diagram opposite.
When any device generates an alarm condion, this will be relayed
to the Master Unit which will also generate an alarm condion
simultaneously. You can use any of the devices as a Master Unit, the
diagram opposite is by way of example only.
Use 7 x 0.2mm stranded alarm cable for all the connecons.
Once the wiring is complete and checked, switch on the power
supply at the mains. Each device will provide a message stang how
it is congured. If you have a gas (smoke) element, the device will
ash its LED for 2 minutes to normalise.
DO NOT TEST THE DEVICE UNTIL THE FLASHING STOPS. Your system is now installed and running normally.
Use the above diagram to connect any of the SD Evoluon products as a master unit to any of the satellite products.
SpeechPOD (Part No CSA-POD) is normally supplied with an
on-board infra red PIR moon sensor as its detecon device.
You can however trigger the SpeechPOD by other sources
instead or in addion to the PIR moon sensor. Examples of
these may be:
Door Contact, Pressure mat, alarm output from security, re
or Building Management Systems, or any other device that
has a Clean or Volt Free Output.
Simply connect the Normally Open (NO) contact across the TRIG IN and GND input. Each me the switch closes,
SpeechPOD will play its programmed message. Remember, SpeechPOD can be baery operated or powered from a 9-
24Vdc power supply connected to the 9-24V IN and GND inputs.
For further informaon or assistance with our products, please contact our Technical Department by phone or email as