P.C.B. SM 20015 boiler settings
6
Parameter 3 setting: HEATING TEMPERATURE SETTING
To modify the Parameter value:
a. Put ON/OFF button
1 in OFF position ( );
b. Push pad 6 and simultaneously and keep them pressed;
c. Put ON/OFF button
1 in ON position ( )and wait until the display shows - ;
d. Release pad
6 and ;
e. Keeping pad
5 pressed, press pad 6 and select parameter no. ;
f. Release service pad
5 ; press and release service pad 5 ;
g. The display
will show the parameter value to be set or modified;
h. Press pad
6 or to modify (increase or decrease) the parameter value STANDARD from 30 to 80°C, REDUCED from 25 to
40°C ;
i. Press and release service pad
5 to confirm setting;
j. The display will show parameter no.
;
k. Position ON/OFF button
1 first in OFF position ( ) and back to ON position ( );
Parameter “4” setting: PUMP SETTING IN HEATING MODE
To modify the Parameter value:
a. Put ON/OFF button
1 in OFF position ( );
b. Push pad 6 and simultaneously and keep them pressed;
c. Put ON/OFF button
1 in ON position ( ) and wait until the display shows - ;
d. Release pad
6 and ;
e. Keeping pad
pressed, press pad 6 and select parameter no. ;
f. Release service pad
; press and release service pad ;
g. The display
will show the parameter value to be set or modified;
h. Press pad
6 or to modify (increase or decrease) the parameter value STANDARD (pump overrun), PERMANENT (pump
ON all the time);
i. Press and release service pad
to confirm setting;
j. The display will show parameter no.
;
k. Position ON/OFF button
1 first in OFF position ( ) and back to ON position ( );