Radiation Alert AM-7149 Specifications

General IconGeneral
Mica window density1.5 - 2.0 mg/cm²
TypeGeiger Counter
Measurement Range0.001 - 100 mR/hr
Energy Range (Beta)0.16 MeV minimum
Accuracy±15% of reading
DisplayBacklit LCD
AudioAdjustable audio output
OutputsRS-232 data output
Power SupplyTwo AA alkaline batteries
Operating Temperature-10°C to 50°C (14°F to 122°F)
Dimensions150 x 80 x 30 mm

Summary

Chapter 1: Introduction

Precautions

Essential safety guidelines and handling instructions for the Area Monitor to maintain its condition.

Chapter 2: Quick Start

Connecting Detector and Power

Initial device setup, including detector connection and power supply connection.

Silencing Alarms

Method for responding to and dismissing active alarms on the device.

Chapter 3: General Operation

Main Screen Functionality

Describes the primary display interface showing radiation rate, units, and power status.

Chapter 6: Setting The Alarm Levels

Set Alarm Levels Screen

Procedure for configuring the specific thresholds for Low, High, and Fail alarms.

Chapter 7: Ethernet Configuration

Chapter 8: Area Monitor PC Software

Installing PC Software

Guide to downloading and installing the software for managing Area Monitors.

Chapter 8: Area Monitor PC Software (Continued)

Calibration and Settings Screen

Details on accessing the screen to adjust calibration parameters and settings.

Sending Alerts Via Email/Text

General guidance on configuring the system to send alerts via email or text.

Setting Up Software Alerts

Detailed steps for configuring alert rules and email recipients within the software.

Chapter 9: Calibration Settings

Setting Up Hardware Alerts

Steps to configure hardware alert rules, including selecting alarm conditions and recipients.

Chapter 9: Calibration Settings (Continued)

Accessing Calibration Settings Screen

Method to access main calibration settings menu via the device's recessed button.

Set High Voltage Screen

Guide to adjusting the high voltage setting for the detector.

Chapter 9: Calibration Settings (Continued)

Set Threshold Screen

Instructions for setting the minimum pulse size required for a count.

Set Cal Constant Screen

Guide to setting the conversion factor for count rates to dose rates.

Set Dead Time Screen

How to configure dead time correction to account for missed counts.

Setup and Calibration Sequence

A numbered list outlining the recommended steps for device setup and calibration.

Chapter 10: Unit Conversions

Appendix A: Technical Specifications

Calibration Parameter Specifications

Technical specifications for key calibration parameters: High Voltage, Threshold, Dead Time, Cal Constant.