Restoring Factory Setup Chapter 9
RADWIN 2000 User Manual Release  2.6.40 9-24
For Site A, click Site A | Inventory and note the ODU software version. Repeat this for Site 
B using Site B | Inventory.
If either ODU has an old software version, perform a software upgrade. It is important to con-
figure the new ODU identically to the old ODU to avoid configuration mismatches, which will 
disrupt the link.
An ODU may be reconfigured in several ways. 
• Use the backup configuration
If a backup of the configuration is available, restore that configuration using Site A| 
Restore. Recall that backup files are linked to a MAC address. This won’t work for 
an identical replacement ODU.
• Manual configuration
The new ODU can be configured manually according to the link configuration. 
Remember to use the same settings for Link ID, channels, link password, IP 
addresses, and names. 
Restoring Factory Setup
To restore factory setup:
• Use Site Configuration A or B, and then Operations | Restore Defaults. Always 
restore the over-the-air site (B) first.
Online Help
Online help can be accessed from the Help menu on the main window of the RADWIN Man-
ager.
Customer Support
Customer support for this product can be obtained from the local VAR, Integrator or distribu-
tor from whom it was purchased.
For further information, please contact the RADWIN distributor nearest to you or one of RAD-
WIN's offices worldwide (see RADWIN Worldwide Offices at the beginning of this man-
ual).