Regulatory Considerations for 3.650-3.675 GHz FCC/IC part 90 sub part Z Chap-
RADWIN 2000 User Manual Release 2.6.40 21-8
“Restricted contention protocols can prevent interference only with other devices incorporat-
ing the same or similar protocols. Equipment using a restricted protocol can operate only on
the lower 25 megahertz (3650-3675 MHz)."
Transmission power options
Table 21-1shows the extent of compliance by RADWIN 2000 C products to FCC/IC power
limits, having regards to antenna type and transmission power options.
Higher Transmission Power Options and Restrictions:
Table 21-2 defines the maximum transmission power and EIRP limits for the specified fre-
quency and channel bandwidths.
It specifies the power limits to be used by the operator when assigning center frequencies.
Table 21-1: FCC/IC compliance by antenna and transmission power
Measured
Frequency Power
Antenna
Nominal
CBW
Low Center
Frequency
Channel
[MHz]
High Center
Frequency
Channel
[MHz]
Max
Conducted Tx
Power per
Pole [dBm]
Total
Conducted
Max Tx Power
[dBm]
Max EIRP
[dBm]
21dBi INT
5 MHz
3653 3672 11.14 14.14 35.14
10 MHz
3655 3670 14.46 17.46 38.46
20 MHz
3660 3665 17.36 20.36 41.36
21dBi EXT (22dBi-
1dB feeder)
5 MHz
3653 3672 11.14 14.14 35.14
10 MHz
3655 3670 14.46 17.46 38.46
20 MHz
3660 3665 17.36 20.36 41.36
24dBi EXT (25 -
1dB feeder loss)
5 MHz
3653 3672 8.65 11.65 35.65
10 MHz
3655 3670 11.36 14.36 38.36
20 MHz
3660 3665 13.73 16.73 40.73
Table 21-2: Higher Transmission Power Limits
Nominal
CBW
Low Center
Frequency
Channel [MHz]
High Center
Frequency
Channel [MHz]
Max Conducted
Tx Power per
Pole [dBm]
Total Conducted
Max Tx Power
[dBm]
Max EIRP
[dBm]
5 MHz
3653 3672 15.60 18.60 35.60
10 MHz
3655 3670 18.69 21.69 38.69
3656 3669 22.00 25.00 38.50
20 MHz
3660 3665 21.18 24.18 41.18
3661 3664 22.60 25.60 39.10