Supported Variables from the RFC 1213 MIB Appendix D
RADWIN 2000 User Manual Release 2.6.40 D-16
winlink1000OduPerfMonIntervalCompressed RO Holds a compressed string of all data per interface.
Compressed Air Interface Structure (size in
brackets): UAS (4) ES (4) SES (4) BBE (4)
Integrity (1) MinRSL (1) MaxRSL (1)
RSLThresh1Exceeded (4)
RSLThresh2Exceeded (4) MinTSL (1) MaxTSL
(1) TSLThresh1Exceed (4)
BBERThresh1Exceed (4) RxMBytes (4)
TxMBytes (4) EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) Compressed
Etherent ODU interface (size in brackets): UAS
(4) ES (4) SES (4) BBE (4) Integrity (1)
RxMBytes (4) TxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) ActiveSeconds (1)
winlink1000OduPerfMonDayTable N/A This table defines/keeps the counters of the last
month (in resolution of days).
winlink1000OduPerfMonDayEntry N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonDayIdx }
winlink1000OduPerfMonDayIdx RO This table is indexed per interval number. Each
interval is of 24 hours and the oldest is 30.
winlink1000OduPerfMonDayUAS RO The current number of Unavailable Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayES RO Current number of Errored Seconds per interval of
24 hours.
winlink1000OduPerfMonDaySES RO Current number of Severely Errored Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayBBE RO Current number of Background Block Errors per
interval of 24 hours.
winlink1000OduPerfMonDayIntegrity RO Indicates the integrity of the entry per interval of 24
hours.
winlink1000OduPerfMonDayCompressed RO Holds a compressed string of all data per interface.
Compressed Air Interface Structure (size in
brackets): UAS (4) ES (4) SES (4) BBE (4)
Integrity (1) MinRSL (1) MaxRSL (1)
RSLThresh1Exceeded (4)
RSLThresh2Exceeded (4) MinTSL (1) MaxTSL
(1) TSLThresh1Exceed (4)
BBERThresh1Exceed (4) RxMBytes (4)
TxMBytes (4) EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) Compressed
Etherent ODU interface (size in brackets): UAS
(4) ES (4) SES (4) BBE (4) Integrity (1)
RxMBytes (4) TxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) ActiveSeconds (1)
winlink1000OduPerfMonAirCurrTable N/A This table defines/keeps the air counters of the
current 15 min interval.
winlink1000OduPerfMonAirCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonAirCurrMinRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.1 Integer RO Current Min Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrMaxRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.2 Integer RO Current Max Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrRSLThresh1Ex
ceed
1.3.6.1.4.1.4458.1000.1.6.4.1.3 Gauge RO Number of seconds Receive Signal Level
exceeded the RSL1 threshold in the last 15
minutes.
Table D-2: Private MIB Parameters (Sheet 11 of 24)
Name OID Type
Access
Description